User manual - Machine Automation Solution - V3R003
19 / 102
GNSS connection
Disconnected GNSS
antenna
Please ensure that the cable is properly connected.
Input controller
Outside the speed
range
You are operating outside the speed range deemed appropriate for good
input application. You may improve the speed range by changing the
system calibration.
Input controller
Motor stopped
The system is unable to detect motor movement. Ensure that the
hydraulic system is on, the motor speed sensor is connected, and no
other alarms are active.
Input controller
No auxiliary power
The input control driver is not getting power to start the motor. Check the
auxiliary power cord connections.
Input controller
Desired rate not
reached
The system is unable to reach the recommended dosage. If you have not
received an alert that the operations is outside the speed range, the
calibration or the minimum and maximum motor speed parameters may
be wrong.
Liquid controller
Outside the speed
range
You are operating outside the proper speed range for good application. You
can improve the speed range by altering the spray nozzle.
Liquid controller
Desired rate not
reached
The system is unable to reach the spray recommendation. If you have not
received an alert that the operation is outside the speed range, the
selected nozzle may be incorrect or there may be a problem with the
pump.
Seed controller
Outside the speed
range
You are operating outside the proper speed range for good planting. You
can improve speed range by changing the seed disks.
Seed controller
Motor stopped
The system is unable to detect motor movement. Ensure that the
hydraulic system is on, the motor speed sensor is connected, and no
other alarms are active.
Seed controller
No auxiliary Power
The seed control driver is not getting power to start the motor. Check the
auxiliary power cord connections.
Seed controller
Desired rate not
reached
The system is unable to reach seed recommendation. If you have not
received an alert that the operation is outside the speed range, the
calibration or the minimum and maximum motor speed parameters may
be wrong.
Short-circuit
Short-circuit
A short-circuit has been detected involving the red/black power fires of
either the CAN bus or the seed sensors. Ensure that the cables are not
damaged.
Incompatible
monitoring
database
Incompatible
monitoring database
Incorrect monitoring database version, which may cause strange behavior
and failure. Please, update to an appropriate version. Insert a pendrive with
an updated database and login with user hxgnguest (blank password). Go
to Menu > System Settings > About > Update Database.
Manual anticide
application error
Empty line
Please ensure that the anticide tank is not empty and the sensor is not
obstructed.
CAN device error
Gate controller
disconnected
The gate controller configured for this implement is disconnected. Ensure
that the CAN bus cables are properly connected and that the module is
not damaged.
CAN device error
Controller
disconnected
The input or seed variable rate controller configured for this implement is
disconnected. Ensure that the CAN bus cables are properly connected
and that the module is not damaged.
CAN device error
Controller
disconnected
The logic controller configured for this implement is disconnected. Ensure
that the CAN bus cables are properly connected and that the module is
not damaged.
CAN device error
Anticide controller
disconnected
The anticide controller configured for this implement is disconnected.
Ensure that the CAN bus cables are properly connected and that the
module is not damaged.
CAN device error
Liquid controller
disconnected
The liquid controller configured for this implement is disconnected. Ensure
that the CAN bus cables are properly connected and that the module is
not damaged.
CAN device error
Section cut off
The section cut controller configured for this implement is disconnected.
Ensure that the CAN bus cables are properly connected and that the
module is not damaged.