Troubleshooting
88
Operating instructions
6 Troubleshooting
If a fault occurs during operation, the fault number and fault message
are displayed.
If the cooking results or cleaning results with WaveClean vary without a
fault message being displayed, use CombiDoctor to analyze the cause.
6.1 Emergency operation
In order to allows limited use in case of error, the unit has several
different emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated, the
controls switch back into normal operation automatically. A reset is not
necessary.
INFORMATION
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
6.2 Cause of error and remedy
Error no.
Fault message displayed
Description
Action
694
695
•
Cooking sensor defective
The internal core temperature
sensor assumes the function of the
defective cooking chamber sensor.
•
Insert the internal core tempera-
ture sensor into its holder.
•
This can lead to a different cook-
ing result.
•
Contact customer service.
699
700
714
716
•
Internal core temperature
sensor defective
The internal core temperature
sensor in the cooking chamber is
deactivated.
•
If possible, use the external core
temperature sensor (optional).
•
Select a different cooking pro-
gram.
•
Contact customer service.