Description of the unit
24
Operating instructions
Cooking mode
Standard value
(°C (°F))
Setting range
(°C (°F))
Change increments
(°C (°F))
Hot air
180 (356)
30 (86 ) - 300
(572)
1 (33,8 )
Regeneration
50 (122 )
30 (86 ) - 180
(356)
1 (33,8 )
3.6.2 Core temperature standard setting
The adjustment range for the core temperature depends on the
cooking mode.
Cooking mode
Standard value
(°C (°F))
Setting range
(°C (°F))
Change increments
(°C (°F))
Steaming
70 (158 )
0 (32 ) - 99
(210,2 )
1 (33,8 )
Combisteaming
70 (158 )
0 (32 ) - 99
(210,2 )
1 (33,8 )
Hot air
70 (158 )
0 (32 ) - 99
(210,2 )
1 (33,8 )
Regeneration
50 (122 )
0 (32 ) - 99
(210,2 )
1 (33,8 )
3.6.3 Cooking chamber humidity standard setting
Cooking chamber humidity setting range depends on the cooking
mode.
Cooking mode
Standard value
(%)
Setting range
(%)
Change increments
(%)
Steaming
100
90 - 110
90 - 100 - 110
Combisteaming
90
20 - 100
20 - 40 - 70 - 90 - 100
Hot air
100
0 - 100
0 - 25 - 50 - 75 - 100
Regeneration
100
0 - 100
0 - 25 - 50 - 75 - 100