Cleaning and caring for the unit
85
Operating instructions
5.12.5 Starting cleaning
The acting time has elapsed, the cleaning process starts
automatically.
The cooking chamber is heated.
The display shows the remaining time.
5.12.6 Drying the cooking chamber
Prerequisite
Cooking chamber door closed
1. The drying process starts automatically.
INFORMATION
The cooking chamber is heated.
2. After the end of the drying process, a signal sounds.
"End" appears on the display.
3. Open the cooking chamber door and leave it ajar until the unit is
used again.
This extends the service life of the door seal.
No moisture builds up in the cooking chamber.
5.13 Removing and installing the air diverter
CAUTION
Pinch hazard from rotating fan
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
• Do not operate the unit without the air diverter.
Removing the air diverter
Prerequisite
Unit dead
1. Remove core temperature sensor from holder.
2. Remove right and left hang-in frames.
3. Remove water supply pipe with the aid of a tool.
4. Take air diverter off the pins.
Installing the air diverter
1. Place the air diverter on the pins.
2. Use tool to close upper fastener.
3. Use tool to close lower fasteners.
4. Use tool to install water supply pipe.
5. Insert right and left support racks.
6. Insert core temperature sensor into holder.
FM05-161-G