Model EEE-182
6-13
The Evolution Elite
®
fryer requires two switching, 24V con-
tactors per vat: a primary and a heat contactor. The primary
contactor energizes (contacts close) any time the main power
switch is in the ON position, and the temperature of the short-
ening is below 420° F ( 215° C). The high limit cuts power at
the primary contactor if the temperature of the shortening is
above 420° F ( 215° C). The primary contactor supplies power
to one side of the heat contactor.
The heat contactor is controlled by the computer controller.
When the button is pressed and the controller calls for
heat, the heat contactor applies power to one side of the heating
elements. When the heat contactor and primary contactor are
energized (contacts closed) the electric heating elements heat
the shortening.
Checkout
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the top, rear panel.
3. Label and remove wires from contactors and perform a
check on both contactors as follows:
Test Points
Results
From 30 to 34
open circuit
From 31 to 35
open circuit
From 32 to 36
open circuit
From 33 to 37 (coil)
ohm reading 5 to 6
To avoid electrical shock, make connections before
applying power, take reading, and remove power
before removing meter leads. The following checks
are performed with the wall circuit breaker closed and
the main power switch in the ON position.
6-11. CONTACTORS
Heat Safety
July 2016
Summary of Contents for EVOLUTION ELITE EEE-181
Page 2: ......
Page 12: ......
Page 14: ......
Page 24: ...Model EEE 182 4 4...
Page 71: ...Model EEE 182 6 29 July 2016...
Page 72: ...Model EEE 182 6 30 July 2016...
Page 73: ...Model EEE 182 6 31 July 2016...
Page 74: ...Model EEE 182 6 32 July 2016...
Page 75: ...Model EEE 182 6 33 July 2016...
Page 76: ...Model EEE 182 6 34 July 2016...
Page 77: ...Model EEE 182 6 35 July 2016...
Page 78: ...Model EEE 182 6 36 July 2016...
Page 79: ...Model EEE 182 6 37 July 2016...
Page 80: ...Model EEE 182 6 38 July 2016...
Page 81: ...Model EEE 182 6 39 July 2016...
Page 82: ...Model EEE 182 6 40 July 2016...
Page 83: ...Model EEE 182 6 41 July 2016...
Page 84: ...Model EEE 182 6 42 July 2016...
Page 90: ...Model EEE 182 7 6 17kw Full Heating Elelemnt Assy July 2016...
Page 92: ...Model EEE 182 7 8 High Limit Control Modules Reset Switches and Wiring July 2016...
Page 117: ......
Page 118: ......