Mixed Filter Tracking
Filter After X Number of Loads
13b. Press button until “FILTER AFTER...” flashes
in the left display along, and the number of cook cycles
between filters shows in the right display. Press the product
buttons, or the and buttons, to change this value of
0 to 99 loads. This needs set for each product.
>Load Compensation, Load Compensation
Reference, Full Heat, PC Factor<
14. Press button until “LD COMP” shows in the display,
along with the load compensation value. This automatical-
ly adjusts the time to account for the size and temperature
of the cooking load.
Press the product buttons, or the and buttons, to
change this value of 0 to 20.
15. Press button until “LCMP REF” shows in the display
along with the load compensation average temperature.
(if load compensation is set to “OFF”, then “_ _ _” shows
in display and setting cannot be programmed) This is the
average cooking temperature for each product. The timer
speeds up at temperatures above this setting and slows
down at temperatures below this setting. Press the product
button, or the and buttons, to change this value.
16. Press button until “FULL HT” shows in the display
along with the full heat value in seconds, which means the
heat is on as soon as a timer button is pressed, for the pro-
grammed length of time. Press the product buttons, or the
and buttons, to change this value of 0 to 90 seconds.
17. Press button until “PC FACTR” shows in the display
along with the proportional temperature, which helps to
keep the oil from over-shooting the setpoint temperature.
Press the product buttons, or the and buttons, to
change this value of 0 to 50 degrees.
• Use button to go back to previous menu items.
• Press button when finished with the current product, to
return to the “SELECT PRODUCT” step.
• Press and hold button to exit PRODUCT PROGRAM
Mode.
4-1. MODIFYING PRODUCT
SETTINGS (Continued)
July 2016
Summary of Contents for EVOLUTION ELITE EEE-181
Page 2: ......
Page 12: ......
Page 14: ......
Page 24: ...Model EEE 182 4 4...
Page 71: ...Model EEE 182 6 29 July 2016...
Page 72: ...Model EEE 182 6 30 July 2016...
Page 73: ...Model EEE 182 6 31 July 2016...
Page 74: ...Model EEE 182 6 32 July 2016...
Page 75: ...Model EEE 182 6 33 July 2016...
Page 76: ...Model EEE 182 6 34 July 2016...
Page 77: ...Model EEE 182 6 35 July 2016...
Page 78: ...Model EEE 182 6 36 July 2016...
Page 79: ...Model EEE 182 6 37 July 2016...
Page 80: ...Model EEE 182 6 38 July 2016...
Page 81: ...Model EEE 182 6 39 July 2016...
Page 82: ...Model EEE 182 6 40 July 2016...
Page 83: ...Model EEE 182 6 41 July 2016...
Page 84: ...Model EEE 182 6 42 July 2016...
Page 90: ...Model EEE 182 7 6 17kw Full Heating Elelemnt Assy July 2016...
Page 92: ...Model EEE 182 7 8 High Limit Control Modules Reset Switches and Wiring July 2016...
Page 117: ......
Page 118: ......