1-4. ERROR CODES
In the event of a control system failure, the digital display
shows an error message. The message codes are shown in the
DISPLAY column below. A constant tone is heard when an er-
ror code is displayed, and to silence this tone, press any button.
DISPLAY
CAUSE
CORRECTION
“E-4”
Control board overheating Turn switch to OFF position, then turn
switch back to ON; if display shows “E-4”,
the control board is getting too hot; check
the louvers on each side of the unit for
obstructions
“E-5”
Oil overheating
Turn switch to OFF position, then turn switch
back to ON; if display shows “E-5”, the
heating circuits and temperature probe should
be checked
“E-6A”
Temperature probe open
Turn switch to OFF position, then turn switch
back to ON; if display shows “E-6A”, the
temperature probe should be checked
“E-6B”
Temperature probe shorted Turn switch to OFF position, then turn switch
back to ON; if display shows “E-6B”, the
temperature probe should be checked
“E-10”
High limit
Let unit cool down (15-20 minutes),
press the
high limit reset switch located on the LH door.
If the high limit does not reset, high limit must
be replaced
“E-15”
Drain Switch
Make sure drain knob is completely pushed-in;
if E-15 persists, have drain switch checked
“E-18-A”
“E-18-B”
“E-18-C”
Left level sensor open
Right level sensor open
Both level sensors open
Turn switch to OFF position, then turn switch
back to ON; if display still indicates a failed
sensor, have the connections checked the
control board; have sensor checked & replaced
if necessory
July 2016
Summary of Contents for EVOLUTION ELITE EEE-181
Page 2: ......
Page 12: ......
Page 14: ......
Page 24: ...Model EEE 182 4 4...
Page 71: ...Model EEE 182 6 29 July 2016...
Page 72: ...Model EEE 182 6 30 July 2016...
Page 73: ...Model EEE 182 6 31 July 2016...
Page 74: ...Model EEE 182 6 32 July 2016...
Page 75: ...Model EEE 182 6 33 July 2016...
Page 76: ...Model EEE 182 6 34 July 2016...
Page 77: ...Model EEE 182 6 35 July 2016...
Page 78: ...Model EEE 182 6 36 July 2016...
Page 79: ...Model EEE 182 6 37 July 2016...
Page 80: ...Model EEE 182 6 38 July 2016...
Page 81: ...Model EEE 182 6 39 July 2016...
Page 82: ...Model EEE 182 6 40 July 2016...
Page 83: ...Model EEE 182 6 41 July 2016...
Page 84: ...Model EEE 182 6 42 July 2016...
Page 90: ...Model EEE 182 7 6 17kw Full Heating Elelemnt Assy July 2016...
Page 92: ...Model EEE 182 7 8 High Limit Control Modules Reset Switches and Wiring July 2016...
Page 117: ......
Page 118: ......