Model CFE-415, 427
54
March 2015
5-3
WARNINGS AND
ERROR MESSAGES
(CONT.)
“E-60”
AIF PC board not
communicating with control PC
board
Press power button to turn vat off, wait 15 seconds,
and turn back on again. If “E-60” persists, have con-
nector between the PCB’s checked; replace AIF PCB
or control PCB board, if necessary
“E-70”
“PWR SW
OR
WIRES FAILED”
Faulty POWER switch or switch
wiring; faulty I/O board
Have POWER switch checked, along with its wiring;
have I/O board checked
“E-75”
HEAT RELAY NEAR
END OF LIFE
Normal wear on secondary
contactor.
Have contactor replaced.
“E-92”
“24 VOLT
FUSE”
Blown 24 volt controller fuse, or
bad 14-pin cable connection
Have the 14-pin cable connector or fryer checked for
a short to ground in components such as the drain
switch, or high limit and wiring
DISPLAY
CAUSE
CORRECTION