Model CFE-415, 427
41
March 2015
2. P-LOG (power-up log)
Press ▼ and “2A. (date & time) *NOW* shows in display. This is the
present date and time.
Press ▼ and the latest power-up is shown, “2B. (date, time,) PWR-
UP”.
Press ▼ and the next latest power-up date is shown. Upto 10 power-ups
(2B to 2K) can be stored in P-LOG section.
Press
to continue onto the heat-up log.
3. HEAT-UP’S
Press ▼ and “3A. (date & time) *NOW* shows in display. This is the
present date and time.
Press ▼ and the latest heat-up is shown, along with the heat-up rate,
ex: “3B. MAY-22, 8:37A 1.25”. The heat rate is the maximum rate
(degrees/second) the controller recorded during the shown time frame.
Press ▼ and the next latest heat-up is shown. Up to 10 heat-ups (3B to
3K) can be stored in the Heat-Up Log.
Press
to continue onto the COOK DATA.
4. LEFT COOK DATA
Press ▼ to step through the following data:
Press
to continue onto the RIGHT COOK DATA.
Function
Display
Time of last Cook Cycle started
4A. STARTED 10.25A
Product (last product cooked)
4B. PRODUCT -1-
Ready? (fryer ready before start?)
4C. READY? YES
Drop detect status
4D. DETECT X NO
Drop adjust (real time seconds)
4E. DROP ADJ T-14
Cook time adj (clock adjust)
4F. CK TM ADJ -13
Actual elapsed cook time (seconds)
4G. ACT TIME 2:23
Stopped: Time remaining, or secs past done
4H. STOP DONE+1
“Slow cook” for this cycle?
4I. SLOW? NO
Overloaded? (Bad batch)
4J. OVRLD? NO
Avg Temp during Cook Cycle
4K. AVG TMP 343°F
Max voltage during Cook Cycle
4L. MAX VOLT 99%
Min voltage during Cook Cycle
4M. MIN VOLT 97%
Max amps during Cook Cycle
4N. MAX AMPS 33
Min amps during Cook Cycle
4O. MIN AMPS 33
41. LOAD SIZE
4-1