Operation 41
1.
Set the value of the Vacuum to the maximum (99.8%) as described in Vacuum on page 40.
2.
Enable . Use the cursor keys
▲
and
▼
to go to the value for the and press
Enter.
3.
Set the desired value using the cursor keys
▲
and
▼
and press Enter.
4.
Press the cursor key
◄
to return to the menu.
5.
Close the lid to start vacuuming.
6.7.2.5 Gas (optional)
For the protection of the product, it may be desirable to insert a gas into the packaging after
vacuuming. Optionally, the machine can be equipped with a gas flush system.
See Technical Data on page 63 for the connection details.
Never use a gas mixture containing more than 20% oxygen or other explosive gases. This
may cause life-threatening explosions.
The insertion of gas lowers the seal pressure. The minimum final pressure (after the
insertion of gas) must be 30% (300 mbar) to ensure proper sealing.
To set the Gas function, follow the steps below:
1.
Press the cursor keys
▲
and
▼
and select the program Gas.
2.
Press Enter to open the menu.
3.
If Gas is not enabled, enable it. Press Enter and use the cursor keys
▲
and
▼
to turn ON Gas.
Press Enter.
4.
Use the cursor keys
▲
and
▼
to go to the value for Gas and press Enter.
5.
Set the desired value using the cursor keys
▲
and
▼
and press Enter.
6.
Press the cursor key
◄
to return to the menu.
7.
Close the lid to start vacuuming.
6.7.2.6 Gas+ (optional)
The Gas+ option only applies if the machine is equipped with the gas option. For some products it
may be desirable to insert additional gas into the packaging to create a "balloon packaging". This
allows for a better protection of a fragile product. The recommended value for Gas+ is 0.7 seconds.
To set the Gas+ option, follow the steps below:
1.
Set the value of Gas in accordance with Gas (optional) on page 41.
2.
Enable Gas+. Use the cursor keys
▲
and
▼
to go to the value for Gas+ and press Enter.
3.
Set the desired value using the cursor keys
▲
and
▼
and press Enter.
4.
Press the cursor key
◄
to return to the menu.
5.
Close the lid to start vacuuming.