Operation 38
2.
Program the External Vacuum program according to the steps specified in 10-Program Control
System on page 33.
3.
Connect the external vacuum hose to the machine by placing the adapter over the suction
inlet (1) in the vacuum chamber.
4.
Connect the external vacuum hose to the packaging.
a.
Connect the adapter (3) of the external vacuum hose to the valve of the packaging.
b.
Slide the sliding valve (2) towards the hose (closed position).
Figure 13: External Vacuum Adapter Set (10-Program Control System)
5.
Press the + / VACUUM STOP button to start vacuuming.
The packaging is vacuumed until the programmed value is reached.
6.
Slide the sliding valve of the adapter towards the packaging (open position) and remove the
external vacuum hose from the packaging.
6.7.1.12 Sleeper Option
If the Sleeper option is enabled, the pump will automatically shut off after the set time has elapsed
and the machine is not in use during this period. The pump will automatically start again once a
new vacuum cycle is started.
By default, the Sleeper option is set to 10 minutes. If you wish to change this time, please contact
your supplier.
The Sleeper option cannot be set to less than 1 minute.
6.7.2 Advanced Control System (ACS)
Users can view the machine programs and activate the functions in the navigation mode. This is
the mode that appears immediately after start-up.