background image

Henden Bluetooth Enabled Variable Speed Pump Installation Manual

 

HENDEN

 INSTALLATION & OWNERS MANUAL 

|

 

9

5. START UP

5.1 Pre-start up checklist 

  

 

Speed setting chosen is a compatible  
setting with other pool equipment 

The pump is installed in a safe and dry environment 

The pump enclosure has adequate drainage  
in the event of leakage 

Any transport plugs are removed 

The pipe-work is correctly sealed and supported 

The pump is primed correctly 

The power supply is correctly connected 

All steps have been taken for safe operation 

The filter has been plumbed with 40/50mm pipe 

6. LOW ENERGY OPERATION

Your Henden Variable Speed Pump has speed settings 
from 1,050 to 3,100rpm:
- 1,050 – Lowest Speed, 1
- 3,100 – Highest Speed, 10
- Variable – Backwash Speed
•  Speed 1 provides the lowest speed and therefore the 

greatest energy efficiency and savings.

Operation

Recommended Speed 

Setting

Backwashing your media 
filter

Backwash Speed

Pool Filtration

Speed 1 to 4

Suction pool cleaner 

operation

Speed 5 to 8

Manually cleaning your 

pool

Speed 9 to 10

Water Feature operation
Spa Jet operation
In-floor cleaning systems
Solar pool heating

Guidelines for Recommended Pump Operating Hours:
Australian Standards AS3633: “Private swimming pools 
- water quality” states that “The minimum turnover rate 
shall be a single turnover of the full volume of the pool 
water, within the period that the pump would normally be 
operating….”
The table below provides a guide only to the running times 
of your pump while in filtration mode in order to achieve 
the minimum turn over rate:

Pool Size 

 (Litres)

Speed Setting (hours)

Speed 1

Speed 5

Speed 10

20,000

2.4

1.3

0.9

30,000

3.7

2.0

1.4

40,000

4.9

2.7

1.9

50,000

6.1

3.3

2.3

60,000

7.4

4.0

2.8

80,000

9.8

5.3

3.8

100,000

12.3

6.7

4.7

Summary of Contents for 8 Star

Page 1: ...n swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 Variable Speed Pump H8VSPBT Bluetooth Enabled A joint government and industry program Hen...

Page 2: ......

Page 3: ...EATURES FUNCTIONALITY 10 7 1 Multi Coloured LED indicator light 10 7 2 Constant Flow Speed Compensation 10 7 3 Patented water cooled design for smooth and super quiet operation 10 7 4 Weatherproof RJ4...

Page 4: ...return the power from the mains switch If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pip...

Page 5: ...Input 1 Brown white Brown white 8 24V Brown Brown Check that the cable you use has the above colour coding pins 1 through to 8 If an alternative colour coding has been used make sure to record the col...

Page 6: ...rol Input Speed control can also be achieved by connecting a 0 10V DC signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial se...

Page 7: ...ial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Speed Setting Input Output hp W hp W Dial 1 0 17 126 0 12 8...

Page 8: ...al pumps your pump will also experience less mechanical wear and tear due to less stress on the internal mechanical components To achieve energy efficient pumping is easy Simply run the filtration pum...

Page 9: ...peed and therefore the greatest energy efficiency and savings Operation Recommended Speed Setting Backwashing your media filter Backwash Speed Pool Filtration Speed 1 to 4 Suction pool cleaner operati...

Page 10: ...the heating process Service diagnostics and software updates For Henden use only 7 5 Backwash Speed Cycling Technology When in backwash mode the pump will cycle between a low and high speed to help ag...

Page 11: ...ime that you require the pump to operate Select the speed setting you would like the pump to run at any time Note Settings of the pump 1 10 refers to slowest to fastest operating speed of the pump Onc...

Page 12: ...will run in manual or schedule mode Disconnect Function The disconnect from pump function can be used to 1 Allow another device to control the pump 2 Disconnect so that you will not automatically con...

Page 13: ...r contact your nearest Reece Irrigation Pools branch Pump Fault Watchdog Error Unplug for 1 minute and plug back in to reset if problem persists call 1300 HENDEN or contact your nearest Reece Irrigati...

Page 14: ...basket connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction 3 Select the speed setting that enables best performance from your suction pool cleaner Speed 3 to 7 should...

Page 15: ...power is available Also check fuses and the main power supply switch 2 Automatic overload is tripped The pump has an in built thermal overload which will reset automatically after the motor has coole...

Page 16: ...s securely attached and in safe working condition c Make sure that all skimmer covers are securely attached and in safe working condition These should be replaced every 3 to 4 years d Remove any obstr...

Page 17: ...improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive...

Page 18: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual 18 HENDEN INSTALLATION OWNERS MANUAL NOTES...

Page 19: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual HENDEN INSTALLATION OWNERS MANUAL 19...

Page 20: ...P N 403214 4...

Reviews: