background image

Henden Bluetooth Enabled Variable Speed Pump Installation Manual

16

 

|

 

HENDEN

 INSTALLATION & OWNERS MANUAL

DANGER Hazardous suction. Do 
not block water entry into filtration 
system with any part of your body 
as the pressure can trap hair or body 
parts, causing severe injury or death. 
Do not block suction.

Turn off pump immediately if 
someone becomes trapped.

Do not use or operate swimming 
pools, spas or spa baths if a suction 
cover is broken, missing or loose. 
Two suction covers and inlets must 
be provided into every pump to avoid 
suction entrapment.

Routine Maintenance tasks - to 
maximise the life of your pool 
equipment & personal safety, use this 
checklist once a week. Turn pump off 
first.

a.  Make sure that any pressure 

gauges are in working condition 
and the operating pressure is 
within limits as specified on the 
product.

b.  Make sure that each suction inlet 

and main drain has a cover that 
is securely attached and in safe 
working condition.

c.  Make sure that all skimmer covers 

are securely attached and in safe 
working condition. These should be 
replaced every 3 to 4 years.

d.  Remove any obstructions or debris 

from the main drain cover.

e.  Ensure the skimmer baskets and 

the pump hair and lint pots are free 
of leaves and debris at least once 
a week.

f.  Remove obstructions and 

combustibles from around the pump 
motor.

g.  Make sure all wiring connections 

are clean and that all wiring and 
electrical equipment is in good 
condition. Damaged wiring must be 
repaired or replaced by a qualified 
electrician as soon as damage is 
discovered.

h.  Check water balance and sanitiser 

levels at your local pool shop.

Caution! Do not add chemicals 
directly to the pool skimmer. Adding 
undiluted chemicals may damage 
pump and filter and void warranty.

In accordance with AS/
NZS60335.2.41 we are obliged to 
inform you that this device is not to 
be used by children or infirm persons 
and must not be used as a toy by 
children.

POWER CONNECTIONS AND WIRING 
MUST BE CARRIED OUT BY 
AN AUTHORISED ELECTRICIAN.

Summary of Contents for 8 Star

Page 1: ...n swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 Variable Speed Pump H8VSPBT Bluetooth Enabled A joint government and industry program Hen...

Page 2: ......

Page 3: ...EATURES FUNCTIONALITY 10 7 1 Multi Coloured LED indicator light 10 7 2 Constant Flow Speed Compensation 10 7 3 Patented water cooled design for smooth and super quiet operation 10 7 4 Weatherproof RJ4...

Page 4: ...return the power from the mains switch If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pip...

Page 5: ...Input 1 Brown white Brown white 8 24V Brown Brown Check that the cable you use has the above colour coding pins 1 through to 8 If an alternative colour coding has been used make sure to record the col...

Page 6: ...rol Input Speed control can also be achieved by connecting a 0 10V DC signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial se...

Page 7: ...ial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Speed Setting Input Output hp W hp W Dial 1 0 17 126 0 12 8...

Page 8: ...al pumps your pump will also experience less mechanical wear and tear due to less stress on the internal mechanical components To achieve energy efficient pumping is easy Simply run the filtration pum...

Page 9: ...peed and therefore the greatest energy efficiency and savings Operation Recommended Speed Setting Backwashing your media filter Backwash Speed Pool Filtration Speed 1 to 4 Suction pool cleaner operati...

Page 10: ...the heating process Service diagnostics and software updates For Henden use only 7 5 Backwash Speed Cycling Technology When in backwash mode the pump will cycle between a low and high speed to help ag...

Page 11: ...ime that you require the pump to operate Select the speed setting you would like the pump to run at any time Note Settings of the pump 1 10 refers to slowest to fastest operating speed of the pump Onc...

Page 12: ...will run in manual or schedule mode Disconnect Function The disconnect from pump function can be used to 1 Allow another device to control the pump 2 Disconnect so that you will not automatically con...

Page 13: ...r contact your nearest Reece Irrigation Pools branch Pump Fault Watchdog Error Unplug for 1 minute and plug back in to reset if problem persists call 1300 HENDEN or contact your nearest Reece Irrigati...

Page 14: ...basket connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction 3 Select the speed setting that enables best performance from your suction pool cleaner Speed 3 to 7 should...

Page 15: ...power is available Also check fuses and the main power supply switch 2 Automatic overload is tripped The pump has an in built thermal overload which will reset automatically after the motor has coole...

Page 16: ...s securely attached and in safe working condition c Make sure that all skimmer covers are securely attached and in safe working condition These should be replaced every 3 to 4 years d Remove any obstr...

Page 17: ...improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive...

Page 18: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual 18 HENDEN INSTALLATION OWNERS MANUAL NOTES...

Page 19: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual HENDEN INSTALLATION OWNERS MANUAL 19...

Page 20: ...P N 403214 4...

Reviews: