Henden 8 Star Installation & Owner'S Manual Download Page 4

Henden Bluetooth Enabled Variable Speed Pump Installation Manual

4

 

|

 

HENDEN

 INSTALLATION & OWNERS MANUAL

1. INSTALLATION OF THE HENDEN 

VARIABLE SPEED PUMP

1.1 Location of the Pump

The pump should be located as close to the water as 
practicable and mounted on a firm base in a well drained 
position, high enough to prevent any flooding. It is the 
installer’s/owner’s responsibility to locate the pump such 
that the nameplate can be easily read and the pump can 
be readily accessed for service.

1.2 Weather Protection

It is recommended that the pump is protected from the 
weather. Enclosures should be ventilated to prevent 
condensation build-up.

1.3 Power Connection

The Henden Variable Speed Pump is suitable for 
connection to a nominal 220-240 volt 50Hz power supply 
and is equipped with a flex cord and 3 pin plug. If a power 
outlet is not available within 3 metres of the pump, a 3 pin 
power point in a safe, dry place may need to be provided 
by an electrician. Extension cords are unsafe around 
pools and should be avoided. If the supply cord of this 
product is damaged it must be replaced by Henden or the 
manufacturer, with genuine Henden spares.
This Henden pool pump incorporates motor overload 
detection designed to protect the motor from overheating. 
If the motor gets too hot during operation, its operating 
speed will reduce to bring it within an acceptable 
operating temperature and then will speed up to the 
originally set speed.
To reset the motor, switch the power off for 30 seconds, 
and then return the power from the mains switch.

If the pump and filter are located below 
pool water level, it is necessary to fit 
isolating valves in the pipe between the 
pump and skimmer box and in return 
pipe from the filter to the pool.

The fittings on this product are 
constructed of ABS. Some PVC jointing 
compounds are incompatible with ABS. 
Check compound suitability before use.

Important Information Your Henden  
pump is double insulated to water 
circuit. If equipotential bonding 
structure is required, then an 
Equipotential Bonding Point is 
provided. (Please refer to your local 
statutes and regulations for AS/NZ 
3000 wiring standards).

Henden recommends that all 
installations are fitted with earth 
leakage or residual current protection 
devices.

Warning! Ensure that an electrical 
isolation switch is located with easy 
access so that the pump can be 
switched off in an emergency.

CAUTION! In the interest of safety, we 
advise that all brands and types of pool 
pumps must be installed in accordance 
with AS3000 wiring rules or equivalent.

When plumbing the discharge pipe, 
ensure that the pipework does not 
interfere with the pumps speed dial.

Barrel unions need to be hand 
tightened. No sealant, glues or  
silicones are required.

2. PIPE CONNECTION

Barrel unions are provided for connecting to the piping 
from the pool. The pumps are designed to accept 
40mm/50mm PVC fittings.

The use of any pipe smaller than those specified above is 
not recommended. Suction piping should be free from all 
air leaks and any humps and hollows which cause suction 
difficulties.
The discharge piping from the pump outlet should be 
connected to the inlet connection on the swimming pool 
filter (usually at the filter control valve).

Summary of Contents for 8 Star

Page 1: ...n swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 Variable Speed Pump H8VSPBT Bluetooth Enabled A joint government and industry program Hen...

Page 2: ......

Page 3: ...EATURES FUNCTIONALITY 10 7 1 Multi Coloured LED indicator light 10 7 2 Constant Flow Speed Compensation 10 7 3 Patented water cooled design for smooth and super quiet operation 10 7 4 Weatherproof RJ4...

Page 4: ...return the power from the mains switch If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pip...

Page 5: ...Input 1 Brown white Brown white 8 24V Brown Brown Check that the cable you use has the above colour coding pins 1 through to 8 If an alternative colour coding has been used make sure to record the col...

Page 6: ...rol Input Speed control can also be achieved by connecting a 0 10V DC signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial se...

Page 7: ...ial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Speed Setting Input Output hp W hp W Dial 1 0 17 126 0 12 8...

Page 8: ...al pumps your pump will also experience less mechanical wear and tear due to less stress on the internal mechanical components To achieve energy efficient pumping is easy Simply run the filtration pum...

Page 9: ...peed and therefore the greatest energy efficiency and savings Operation Recommended Speed Setting Backwashing your media filter Backwash Speed Pool Filtration Speed 1 to 4 Suction pool cleaner operati...

Page 10: ...the heating process Service diagnostics and software updates For Henden use only 7 5 Backwash Speed Cycling Technology When in backwash mode the pump will cycle between a low and high speed to help ag...

Page 11: ...ime that you require the pump to operate Select the speed setting you would like the pump to run at any time Note Settings of the pump 1 10 refers to slowest to fastest operating speed of the pump Onc...

Page 12: ...will run in manual or schedule mode Disconnect Function The disconnect from pump function can be used to 1 Allow another device to control the pump 2 Disconnect so that you will not automatically con...

Page 13: ...r contact your nearest Reece Irrigation Pools branch Pump Fault Watchdog Error Unplug for 1 minute and plug back in to reset if problem persists call 1300 HENDEN or contact your nearest Reece Irrigati...

Page 14: ...basket connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction 3 Select the speed setting that enables best performance from your suction pool cleaner Speed 3 to 7 should...

Page 15: ...power is available Also check fuses and the main power supply switch 2 Automatic overload is tripped The pump has an in built thermal overload which will reset automatically after the motor has coole...

Page 16: ...s securely attached and in safe working condition c Make sure that all skimmer covers are securely attached and in safe working condition These should be replaced every 3 to 4 years d Remove any obstr...

Page 17: ...improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive...

Page 18: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual 18 HENDEN INSTALLATION OWNERS MANUAL NOTES...

Page 19: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual HENDEN INSTALLATION OWNERS MANUAL 19...

Page 20: ...P N 403214 4...

Reviews: