background image

 

HENDEN

 INSTALLATION & OWNERS MANUAL 

|

 

3

Contents

Henden 8

 Bluetooth

®

 Enabled Variable Speed Pumps

INSTALLATION
1. INSTALLATION OF THE HENDEN  

H8VSPBT PUMP 

4

1.1   Location of the pump 

4

1.2   Weather Protection 

4

1.3   Power Connection 

4

2. PIPE CONNECTION 

4

3. TYPICAL INSTALLATION DIAGRAM 

5

4. ADVANCED SETUP 

5

4.1   External AUX Connections Overview 

5

4.2   Digital Control Inputs 

5

4.3   Interfacing equipment to the  

Henden Variable Speed Pump 

6

4.4   Analogue Control Input 

6

TECHNICAL SPECIFICATIONS 

6

OWNERS MANUAL
5. START UP 

9

5.1   Pre-start up checklist 

6. LOW ENERGY OPERATION 

9

7. FEATURES & FUNCTIONALITY 

10

7.1   Multi-Coloured LED indicator light 

10

7.2   Constant Flow/Speed Compensation 

10

7.3   Patented water cooled design for smooth  

and super quiet operation 

10

7.4   Weatherproof RJ45 Communication Port 

10

7.5   Backwash Speed Cycling Technology 

10

7.6   Full variable frequency drive with user  

friendly selectable speed dial 

10

7.7   Large 4.5 litre lint pot 

10

8. BLUETOOTH

®

 FUNCTIONALITY 

10

8.1   Bluetooth App Set Up 

10

8.2   Setting a Schedule 

11

8.3   Settings 

11

8.4   Pump Fault Finding 

12

9. USING YOUR PUMP WITH A 

SALT WATER CHLORINATOR 

14

10. OPERATING YOUR SUCTION POOL CLEANER 

14

11. MAINTENANCE: EMPTYING THE STRAINER BASKET 

14

12.  TROUBLE SHOOTING 

15

13. REMOVAL OF THE PUMP FROM PIPEWORK 

15

14. WATER QUALITY 

15

15. HENDEN

 REPAIR OR REPLACEMENT GUARANTEE 

17

Summary of Contents for 8 Star

Page 1: ...n swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 Variable Speed Pump H8VSPBT Bluetooth Enabled A joint government and industry program Hen...

Page 2: ......

Page 3: ...EATURES FUNCTIONALITY 10 7 1 Multi Coloured LED indicator light 10 7 2 Constant Flow Speed Compensation 10 7 3 Patented water cooled design for smooth and super quiet operation 10 7 4 Weatherproof RJ4...

Page 4: ...return the power from the mains switch If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pip...

Page 5: ...Input 1 Brown white Brown white 8 24V Brown Brown Check that the cable you use has the above colour coding pins 1 through to 8 If an alternative colour coding has been used make sure to record the col...

Page 6: ...rol Input Speed control can also be achieved by connecting a 0 10V DC signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial se...

Page 7: ...ial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Speed Setting Input Output hp W hp W Dial 1 0 17 126 0 12 8...

Page 8: ...al pumps your pump will also experience less mechanical wear and tear due to less stress on the internal mechanical components To achieve energy efficient pumping is easy Simply run the filtration pum...

Page 9: ...peed and therefore the greatest energy efficiency and savings Operation Recommended Speed Setting Backwashing your media filter Backwash Speed Pool Filtration Speed 1 to 4 Suction pool cleaner operati...

Page 10: ...the heating process Service diagnostics and software updates For Henden use only 7 5 Backwash Speed Cycling Technology When in backwash mode the pump will cycle between a low and high speed to help ag...

Page 11: ...ime that you require the pump to operate Select the speed setting you would like the pump to run at any time Note Settings of the pump 1 10 refers to slowest to fastest operating speed of the pump Onc...

Page 12: ...will run in manual or schedule mode Disconnect Function The disconnect from pump function can be used to 1 Allow another device to control the pump 2 Disconnect so that you will not automatically con...

Page 13: ...r contact your nearest Reece Irrigation Pools branch Pump Fault Watchdog Error Unplug for 1 minute and plug back in to reset if problem persists call 1300 HENDEN or contact your nearest Reece Irrigati...

Page 14: ...basket connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction 3 Select the speed setting that enables best performance from your suction pool cleaner Speed 3 to 7 should...

Page 15: ...power is available Also check fuses and the main power supply switch 2 Automatic overload is tripped The pump has an in built thermal overload which will reset automatically after the motor has coole...

Page 16: ...s securely attached and in safe working condition c Make sure that all skimmer covers are securely attached and in safe working condition These should be replaced every 3 to 4 years d Remove any obstr...

Page 17: ...improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive...

Page 18: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual 18 HENDEN INSTALLATION OWNERS MANUAL NOTES...

Page 19: ...Henden Bluetooth Enabled Variable Speed Pump Installation Manual HENDEN INSTALLATION OWNERS MANUAL 19...

Page 20: ...P N 403214 4...