14

AUX MAV SEP SOURCE
SET 

STEP 14CS

TRIGGER

STEP 14CS  – Separate source selection requires connection of motorized alternator valve 

(MAV) to Auxiliary Drive two-pin connection on board.

Auxiliary MAV Drive set to operate with a Separate Source trigger.  Auxiliary MAV transitions 

to Bypass before the start of regen cycle #1, AFTER Alternator MAV motor transition.  Auxiliary 

MAV transitions back to Service at the completion of the last programmed regen cycle, once 

the Valve Motor deactivates and BEFORE Alternator MAV transition (if scheduled).  Auxiliary 

MAV will NOT automatically return to Service while manually stepping valve through regen, 

MAV will remain in Bypass until regen cycle end.  Press NEXT to go to Step 15CS.  Press 

REGEN to return to previous step.

AUX MAV RECLAIM
SET 

STEP 11CS

TRIGGER

STEP 12CS  – Only displays if reclamation of brine is enabled in Step 11CS. Use the 

 

or 

 

buttons to select the number of minutes after the start of regeneration before 

the MAV will divert the waste water from the plumbing drain receptacle to the storage 

tank.  Start of regeneration is defined as any mode that is not fill or softening.
Press NEXT to go to Step 13CS.  Press REGEN to return to previous step.

STEP 13CS  – Only displays if reclamation is enabled in Step 11CS.  Use the 

 

or 

 

buttons to select the number of minutes to divert the waste water to the storage tank.  

After the minutes count down to zero the waste water will once again be diverted to 

the plumbing drain receptacle.  Press NEXT to program next reclamation event if more 

than one selected.  Press NEXT to go to Step 15CS is only one reclaim event desired.  

Press REGEN to return to previous step.
Only displays if RECLAIM 2X is selected.  Use the 

 

or 

 

buttons to select number of 

minutes after start of regeneration for Aux MAV to divert waste water.  Press NEXT to 

program number of minutes for duration of second reclaim event.  Use the 

 

or 

 

but-

tons to select number of minutes of duration of second reclaim event.  Press NEXT to 

program third reclaim event or to go to Step 15CS if not further reclaim required.

SYSTEM BOARD
SET 

STEP 9CS

ENABLED

TRIGGER

AUX MAV OFF
SET 

STEP 10CS

STEP 9CS  – Configuring the Control Valve to operate with the Hellenbrand SystemMate 

Controller - Select System Board Enabled to link the Control Valve to the SystemMate Con-

troller.  For communication between the Control Valve and the System Controller, a three wire 

communication cable is required.  
Press NEXT to go to Step 10CS.  Press REGEN to return to previous step.

STEP 10CS  – Use the 

 

or 

 

buttons to select one of the following:

• Reclaim – Allows water or regenerant reclaimation.  Up to 3 reclaim events can be 

  programmed – See instructions below.

• Separate Source –Allows Auxiliary MAV to switch positions before the start of regeneration 

and to switch back at the end of regeneration.  See instructions in Step 14CS.

• Off - Factory Setting is Off

Press NEXT to go to Step 11CS when reclaim selected as trigger.  Press REGEN to return to 

previous step. 

STEP 11CS  – Use the 

 

or 

 

buttons to select reclaim as Aux MAV Trigger.  This option is 

usually done with softeners for brine reclaim but can be used to reclaim water used during 

regeneration.  Three reclaim events are possible.  RECLAIM is one event.  RECLAIM 2X is two 

events and RECLAIM 3X is selected for 3 different reclaim events.

AUX RECLAIM START
SET 

STEP 12CS

30:00

MIN

AUX RECLAIM DURATION
SET 

STEP 13CS

6:00

MIN

MAX RECLAIM 2 START
SET 

38:00

MIN

RECLAIM 2 DURATION
SET 

15:00

MIN

Summary of Contents for ProMate-6.0

Page 1: ...Owner s Filter Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com FILTER SYSTEM 107207 Rev B 5 8 18 2007 2018...

Page 2: ...assistance for servicing your water filter please contact the dealer who installed this system Job Specification Sheet 2 Pre Installation Check List 3 Installation Instructions 4 Programming 5 Initia...

Page 3: ...recommended with all electric controls Existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up heavily with lime and or iron must be replaced...

Page 4: ...joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part of the o rings split rings bypass valve or...

Page 5: ...cally When water is being treated i e water is flowing through the system the word GPM flashes on left side of display when other than flow rate is displayed Figure 8 DAYS TO A REGEN 6 CAPACITY REMAIN...

Page 6: ...to prevent multiple units from regenerating at the same time Step 5I Regeneration Time minutes Set the minutes of day for regeneration using or buttons This display will not be shown if system is set...

Page 7: ...vide treated water when the regeneration has been completed Figure 11 STEP 1S STEP 2S FILTERING STEP 3S SET 12 00MIN STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not a...

Page 8: ...tivates after set time Press NEXT for programming Relay Triggered on Gallons Relay activates every set number of gallons while in service and deactivates after set time Press NEXT to go to 11S for pro...

Page 9: ...arrows to set duration of relay activation in minutes Range 0 01 1 second 500 00 500 minutes Press NEXT to go to Step 20S Press REGEN to return to previous step STEP 13S If REGEN gallons chosen to act...

Page 10: ...his display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6 D Press REGEN to return to the previous step DIAGNOSTICS STEP 1D STEP 2D 2 DAYS SINCE R...

Page 11: ...on at time of stall Press NEXT to exit valve history STEP 1VH VALVE HISTORY STEP 2VH 970 TOTAL DAYS STEP 3VH 235 STEP 4VH 175 GAL x1K RETURN TO NORMAL MODE Can not be reset TOTAL REGENS TOTAL GALLONS...

Page 12: ...No Hard Water Bypass During Regeneration See instructions in Step 6CS Reclaim Enabled Allows control to operate in Reclamation Mode up to 3 reclaim events can be programmed See instructions in Step 8C...

Page 13: ...ating MAV will transition back to Service after the completion of the preset duration time labeled Reclaim Duration Three reclaim events are possible Select either Reclaim Enabled Reclaimed 2x for two...

Page 14: ...to return to previous step Only displays if RECLAIM 2X is selected Use the or buttons to select number of minutes after start of regeneration for Aux MAV to divert waste water Press NEXT to program n...

Page 15: ...or buttons until selection of fourth cycle appears in left upper corner in this example RINSE is selected Press NEXT to go to Step 18CS Press REGEN to return to previous step STEP 18CS Press the or bu...

Page 16: ...osen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high drive forces C3 Motor failure during regeneration replace motor Error Code 104 Motor ran too long D1 Piston unable...

Page 17: ...ce battery if less than 3 volts F Defective PC board F Replace PC board 3 Control does not display correctly A Power outage 2 years A Reset time of day replace lithium coin type battery time of day on...

Page 18: ...r assembly C Defective relay See figure below C Replace Relay D Defective PC Board D Replace PC Board E Faulty wire connections between E Check and repair wire connections PC board and relay 7 Relay e...

Page 19: ...6 21 x 62 1 110569 5 Filter Media Contact dealer for filter media type quantity 6 Underbedding Contact dealer for underbedding type quantity Vortech tank does not use underbedding Owners Manual 1 1072...

Page 20: ...OVER AND DRIVE ASSEMBLY After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons press and hold NEXT and REGEN buttons for 3 seconds or unplug power so...

Page 21: ...The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten o...

Page 22: ...on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o rings...

Page 23: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Page 24: ...ants on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o ri...

Page 25: ...ble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications Loosens Driv...

Page 26: ...minutes of no water usage when gallon capacity reaches 0 1 to 28 1 to 28 1 to 28 20 to 250 000 20 to 250 000 20 to 250 000 20 to 250 000 Reserve Gallons Regeneration Type Days Override Results Reserv...

Page 27: ...27 NOTES...

Page 28: ...s paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act o...

Reviews: