After resolving the cause of any error code or any service valve, press NEXT & REGEN simultaneously for 5 seconds or disconnect power supply for 

5 seconds at PC board and reconnect to resynchronize software with piston position.

VALVE ERROR CODES

 Error Code 101 - Unable to recognize 

A1.   Control not reading piston position 

A1.  Resynchronize software with piston position by 

start of regeneration 

 

 

 

pressing start of regeneration NEXT and REGEN 

     

 

 

 

buttons simultaneously for 5 seconds, until screen

     

 

 

 

changes.  Initiate regeneration to verify function by    

     

 

 

 

pressing and holding REGEN button until regeneration  

     

 

 

 

initiates, step through regeneration modes by pushing  

     

 

 

 

REGEN button each time motor stops. 

    

   

A2. Verify motor connection to PC board; motor wires intact   

     

 

 

 

and motor fully inserted to engage pinion.

     

 

 

A3.  Verify correct assembly; PC board snapped onto drive    

     

 

 

 

bracket and wires are in backplate guides and drive 

     

 

 

 

bracket snapped onto backplate.  Verify three drive    

     

 

 

 

gears are in place on drive bracket.

Error Code 102 - Unexpected stall 

B1.  Mechanical Binding 

B1a. Check for any foreign material in stack assembly impeding 

     

 

 

 

piston movement and remove; verify seals intact and

     

 

 

 

in place, if not, replace stack assembly and piston.

    

   

B1b. Check for incorrect assembly, drive bracket not snapped   

     

 

 

 

into place, motor pushed inside of barrel of drive bracket

      

 

 

 

(black gear on motor end should be flush with end of shaft).

     

 

 

B1c. Drive gears unable to rotate freely - replace gear(s) if not    

  

 

  

 rotating 

freely.

    

B2.  Buildup on piston 

B2.  Clean with soft cloth and vinegar, or replace piston

    

B3.  Improper voltage being delivered 

B3.  Motor unable to move piston, check voltage is present

     

 

to board 

 

on 12V DC motor at start of regeneration modes. 

      

 

 

 

Transformer should provide 12 volts when plugged    

     

 

 

 

into outlet and not attached to board - if not replace    

  

 

  

 transformer

Error Code 103 - Motor ran too long, 

C1. High drive forces on piston 

C1. Loosen drive cap gear 1/4 turn 

timed out trying to reach next position 

 

 

C2. Address high drive forces

     

 

 

C3. Motor failure during regeneration-replace motor

Error Code 104 - Motor ran too long, 

D1. Piston unable to reach home position 

D1. Incorrect assembly; check drive bracket is correctly

timed out trying to reach home position 

 

 

 

seated and snapped into place on backplate, wires

     

 

 

 

outside of guides on backplate can impede drive

     

 

 

 

bracket from correct position.

     

 

 

D2. Check PC board is seated on posts and snapped 

     

 

 

 

into place on drive bracket

     

 

 

D3. Drive gear labels dirty or missing, missing or broken

     

 

 

 

gear, replace as needed

MAV ERROR CODES

After resolving any MAV error or servicing MAV, resynchronize software with piston positioning by pressing NEXT and REGEN buttons simultaneously for 5 seconds 

or disconnecting power from PC board for 5 seconds and reconnecting.

ALTERNATING MAV DRIVE - ERROR CODES 106 & 107

Error Code 106 - Alternating MAV ran too long 

 

A1.  Control valve is programmed for alternating or as 

     

 

 

 

NHWB without having MAV connected to board.

     

 

 

 

Reprogram valve to proper setting or connect MAV

     

 

 

 

to alternating MAV drive on PC board

     

 

 

A2.  MAV motor not fully engaged with gears

Error Code 107 - Alternating MAV stalled 

B. Mechanical Binding 

B1.  Open MAV and check for foreign material on stack

     

 

 

 

assembly, remove if present, verify seals intact and in

     

 

 

 

place.  If not, replace stack assembly

     

 

 

B2.  Drive gear should spin freely-replace if necessary

AUXILIARY  MAV DRIVE - ERROR CODES 116 & 117

Error Code 116 - Auxiliary MAV ran to long   

 

A1.  Control valve is programmed for auxiliary MAV without

     

 

 

 

having MAV connected to board.  Reprogram valve to

     

 

 

 

proper setting or connect MAV to two-pin connection

     

 

 

 

labeled auxiliary drive on PC board

     

 

 

A2.  MAV motor not fully engaged with gears

Error Code 117 - Auxiliary MAV stalled 

 

 

B1.  Open MAV and check for foreign material on stack 

     

 

 

 

assembly, remove if present, verify seals intact and in

     

 

 

 

place.  If not, replace stack assembly

     

B2. Mechanical Binding 

B2.  Drive gear and reducing gears should spin freely, 

     

 

 

 

replace if necessary

TROUBLE SHOOTING

 PROBLEM 

CAUSE 

CORRECTION

Summary of Contents for ProMate-6.0

Page 1: ...Owner s Filter Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com FILTER SYSTEM 107207 Rev B 5 8 18 2007 2018...

Page 2: ...assistance for servicing your water filter please contact the dealer who installed this system Job Specification Sheet 2 Pre Installation Check List 3 Installation Instructions 4 Programming 5 Initia...

Page 3: ...recommended with all electric controls Existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up heavily with lime and or iron must be replaced...

Page 4: ...joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part of the o rings split rings bypass valve or...

Page 5: ...cally When water is being treated i e water is flowing through the system the word GPM flashes on left side of display when other than flow rate is displayed Figure 8 DAYS TO A REGEN 6 CAPACITY REMAIN...

Page 6: ...to prevent multiple units from regenerating at the same time Step 5I Regeneration Time minutes Set the minutes of day for regeneration using or buttons This display will not be shown if system is set...

Page 7: ...vide treated water when the regeneration has been completed Figure 11 STEP 1S STEP 2S FILTERING STEP 3S SET 12 00MIN STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not a...

Page 8: ...tivates after set time Press NEXT for programming Relay Triggered on Gallons Relay activates every set number of gallons while in service and deactivates after set time Press NEXT to go to 11S for pro...

Page 9: ...arrows to set duration of relay activation in minutes Range 0 01 1 second 500 00 500 minutes Press NEXT to go to Step 20S Press REGEN to return to previous step STEP 13S If REGEN gallons chosen to act...

Page 10: ...his display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6 D Press REGEN to return to the previous step DIAGNOSTICS STEP 1D STEP 2D 2 DAYS SINCE R...

Page 11: ...on at time of stall Press NEXT to exit valve history STEP 1VH VALVE HISTORY STEP 2VH 970 TOTAL DAYS STEP 3VH 235 STEP 4VH 175 GAL x1K RETURN TO NORMAL MODE Can not be reset TOTAL REGENS TOTAL GALLONS...

Page 12: ...No Hard Water Bypass During Regeneration See instructions in Step 6CS Reclaim Enabled Allows control to operate in Reclamation Mode up to 3 reclaim events can be programmed See instructions in Step 8C...

Page 13: ...ating MAV will transition back to Service after the completion of the preset duration time labeled Reclaim Duration Three reclaim events are possible Select either Reclaim Enabled Reclaimed 2x for two...

Page 14: ...to return to previous step Only displays if RECLAIM 2X is selected Use the or buttons to select number of minutes after start of regeneration for Aux MAV to divert waste water Press NEXT to program n...

Page 15: ...or buttons until selection of fourth cycle appears in left upper corner in this example RINSE is selected Press NEXT to go to Step 18CS Press REGEN to return to previous step STEP 18CS Press the or bu...

Page 16: ...osen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high drive forces C3 Motor failure during regeneration replace motor Error Code 104 Motor ran too long D1 Piston unable...

Page 17: ...ce battery if less than 3 volts F Defective PC board F Replace PC board 3 Control does not display correctly A Power outage 2 years A Reset time of day replace lithium coin type battery time of day on...

Page 18: ...r assembly C Defective relay See figure below C Replace Relay D Defective PC Board D Replace PC Board E Faulty wire connections between E Check and repair wire connections PC board and relay 7 Relay e...

Page 19: ...6 21 x 62 1 110569 5 Filter Media Contact dealer for filter media type quantity 6 Underbedding Contact dealer for underbedding type quantity Vortech tank does not use underbedding Owners Manual 1 1072...

Page 20: ...OVER AND DRIVE ASSEMBLY After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons press and hold NEXT and REGEN buttons for 3 seconds or unplug power so...

Page 21: ...The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten o...

Page 22: ...on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o rings...

Page 23: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Page 24: ...ants on threads Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connection Teflon tape is not necessary on the nut connection nor caps because of o ri...

Page 25: ...ble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications Loosens Driv...

Page 26: ...minutes of no water usage when gallon capacity reaches 0 1 to 28 1 to 28 1 to 28 20 to 250 000 20 to 250 000 20 to 250 000 20 to 250 000 Reserve Gallons Regeneration Type Days Override Results Reserv...

Page 27: ...27 NOTES...

Page 28: ...s paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act o...

Reviews: