CYCLE SEQUENCE
Anytime cycle sequence is modified, filter set-up will revert to manu-
facturer setting and must be reprogrammed as desired.
Cycle Sequence instructions allows the operator to set the order of the
cycles. The Filter System Setup allows the operator to set how long the
cycles will last. The operator may choose up to 9 cycles in any order.
END must be used as the last cycle option. The FILTERING cycle should
only be used in regenerant prefill applications.
Cycle Options
BACKWASH
FILL
RINSE
FILTERING
END
REGENERANT
DRAW
The following is an example of how to set a valve so that when regeneration is initiated, BACKWASH occurs first, REGENERANT
DRAW DN occurs second, RINSE occurs third, and FILL occurs fourth.
STEP 1CS – Press NEXT and
simultaneously until TYPE appears on screen and release.
Then press NEXT and
simultaneously again for 3 seconds and release. If screen in step 2CS
does not appear in 5 seconds the lock on the valve is activated.
STEP 2CS – Valve Type. Use the
or
to select from 1.0", 1.25", 1.50", 2.0L", 2.0" valve.
ProMate-6.0 is a 1.0” meter. Press NEXT to go to Step 3CS.
STEP 3CS – Use the
or
to select one of the following:
• Twin Alternating System – Select Alt A or Alt B, See instructions in Step 4CS; or
• System Board - Allows Demand Recall Programming – See instructions in Step 9CS.
• No Hard Water Bypass During Regeneration – See instructions in Step 6CS.
• Reclaim Enabled - Allows control to operate in Reclamation Mode, up to 3 reclaim events can be
programmed – See instructions in Step 8CS.
• Separate Source Enabled - Allows control to have a separate water source during the
regeneration cycle. See instructions in Step 7CS.
• System Board Enabled - See Step 9CS.
• OFF; Factory Setting is OFF - Press NEXT to go to Step 10CS.
STEP 4CS –Twin Alternating System – Allows automatic alternation between two units to provide
softened water 24 hours a day.
Use
or
buttons to select ALT A or ALT B. Press NEXT to select alternating options.
Select ALT A for the control valve that has the two-pin connector labeled MAV DRIVE connected to
the alternator valve.
Select ALT B for the control valve that will be connected via three-prong connector labeled
INTERCONNECT. Must use 3-wire interconnect cable. Press NEXT to go to Step 5CS.
For Alternating System, change programming:
• Set softener, with volume capacity in GALLONS and select
Regeneration Time Option “IMMEDIATE” or "DELAYED" and select DAYS BETWEEN REGEN
as desired.
• For complete programming, see Twin Alternating MAV manual.
STEP 1CS
➔
STEP 2CS
1.0
SET
STEP 3CS
OFF
ALTERNATOR SYSTEM
SET
VALVE TYPE
ALT A
ALTERNATOR SYSTEM
SET
STEP 4CS
IN
Select Twin Alternating Options
• Standard - Standard Alternating function
• Refresh Rinse - Alternates every 6am & 6pm and runs programmable number of
gallons to service before alternating back.
• Delayed Rinse and Fill - See Step 5CS
➔
➔
➔