MODEL
AIFII 10 MAXIS O3
AIFII 13 MAXIS O3
Backwash Minutes
8.00
8.00
Rinse DN Minutes
4.00
4.00
Draw DN Minutes
30
30
*Water Usage (Gallons)
74.4
113.4
Media, Cubic Feet
1
1.8
Mineral Tank Dimension
10x54
13x54
Drain Line Flow Control (GPM)
3.2
4.2
Injector
Orange
Dk. Green
Max. Service Flow Rate @15 psi loss (GPM)
5.0
8.0
Max. Iron Concentration (PPM)
5.0
5.0
Max. Hydrogen Sulfide Concentration (PPM)
1.0
1.0
pH Range
6 to 9
6 to 9
Max. Manganese Concentration (PPM)
1.0
1.0
Max. Capacity Between Regen Cycles (GAL)
500.0
500.0
Based upon 50 psi water pressure
conditions may require different application parameters.
All electric and plumbing must be done in accordance with local codes.
Hydrogen Sulfide
1.0 mg/L +/- 10%
0.05 mg/L
Iron
3 to 5 mg/L
0.3 mg/L
08/02/21 Rev A
800905
ERADICATOR O3 IRON REMOVAL SPECIFICATIONS
FACTORY PRESET MINUTES
Do not use Eradicator with Ozone filter on chlorinated water supplies.
For levels higher than the maxium concentrations listed, contact manufacturer. Local water
Requirements for proper
operation:
Water Pressure:
The system
will operate on a minimum of 20
psi and a maximum of 100 psi.
Flow Rate:
A minimum of 5
gallons per minute is required
for proper system operation. If
less than 0.5 gpm is available,
consult with your dealer for
custom settings or
configurations.
Water Temperature:
The range
of water temperature to operate
this system on is 40º to 110ºF.
This system has been tested according to NSF/ANSI 42 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
Influent Challenge
Concentration
Maximum Permissible
Product Water Concentration
Substance
Drain
: A drain should be within
20' of the system using 3/4"
tubing. Maximum overhead
height is 8'. Consult your
dealer for any drain over 30'.
Electricity:
An uninterrupted
110 volt AC source is required
to operate this system. Note:
Make sure electrical source is
not on a timer or a switch.
Do not use with water that is
microbiologically unsafe or of
unknown quality without
adequate disinfection before or
after the system.
Specifications