Eradicator Gen II O
3
Manual Supplement
Install & Service Guide
14
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
Gen II O
3
with Ozone
Plug the power supply into the receptacle. Refer to the main Eradicator manual for the instructions
for the start up procedure.
The programming for the O
3
is already done for Eradicator O
3
systems, so no further action is
needed beyond the normal start up procedure.
Once set up is complete, start the Eradicator in a manual regeneration and let it complete the
regeneration.
It is highly recommended to have an annual inspection and maintenance on the Eradicator system
to keep it operating at optimum performance.
If any service or maintenance is required, have your customer contact you for this service.
The O
3
programming chart is below. The first program column is the default setting.
The other two are optional settings
if needed or recommended.
Setting Cycle Sequence
Next & Down 3 seconds &
repeat*
AIF Filter
AIF Filter
AIF Filter
Meter Size
Match Size
Match Size
Match Size
Auxiliary Input
OFF
OFF
OFF
Cycle 1
Backwash
Backwash
Backwash
Cycle 2
Rinse
Rinse
Rinse
Cycle 3
REGEN DN
REGEN DN
REGEN DN
Cycle 4
END
END
END
Programming Control
Next & Down 3 Seconds*
AIF Filter
AIF Filter
AIF Filter
Set
Filtering
Filtering
Filtering
Backwash
8
8
8
Rinse
4
4
4
REGEN DN
30
40
60
Gallons Capacity
500
500
500
REGEN Type
Delayed
Delayed
Delayed
Relay 1
Regen Time
Regen Time
Regen Time
Relay 1 Setpoint
13 MIN
13 MIN
13 MIN
Relay 1 Duration
28 MIN
38
58
Relay 2
OFF
OFF
OFF
Service Alarm
OFF
OFF
OFF
Default Install Settings - Step 4
Next & UP*
AIF Filter
AIF Filter
AIF Filter
Days Between Regen
OFF
OFF
OFF
Regen Time
1:00 AM
1:00 AM
1:00 AM
Energy Saver
OFF
OFF
OFF
Setup Procedures
Start Up