Eradicator Gen II O
3
Manual Supplement
Install & Service Guide
21
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
Gen II O
3
with Ozone
Troubleshooting
Status Light
Condition
Green light blinking slowly
Standby mode; unit is powered, pilot input is OFF.
Green light blinking quickly
High voltage startup (up to 3 seconds)
Green light solid
High voltage is ON & stable; CD cell producing ozone
Red light solid
Unstable operation; CD cell may need cleaning
Green/Red light alternating
twice per second
HV is ON, but operating current is low. If persistent, CD cell may
need cleaning
Red light flashing
NO or NC contacts are shorted. Remove short condition
Orange light
1-year timer has expired; clean CD cell, then reset timer by
pressing red “alarm reset” button on PCB once
+
+
PILOT
GND
GND
N.C.
N.O.
WARNING
!
ELECTRICAL
HAZARD
DISCONNECT POWER
BEFORE SERVICING
OZOTECH
Alarm
Reset
Diagnostic LED
(Status Light)
This table shows the Status light (diagnostic)
parameters and their meaning. The Status light
will tell you the state the EOG II system is in.
It is useful to check normal operation and if there
is service needed.