NANOV TOP DV GAS APPLIANCE INSTALLATION INSTRUCTIONS
Step 9 - Attaching the Labels
a.
The installer conversion label and valve
manufacturer labels must be completed and
installed by the individual completing the
conversion.
This must be finished or the
conversion is not complete.
See Figures 35-37.
b.
To fill out the installer conversion label, follow the
example in Figure 35. After filling out the label,
clean an area near the existing rating label and
attach.
Attach the valve manufacturer conversion
labels as indicated in Figure 37.
Figure 35 - Conversion Label
THIS CONTROL
HAS BEEN CON-
VERTED
TO
LP
Figure 36 - Robertshaw Conversion Label
Figure 37
Robertshaw Conversion Label Placement
CKP
THIS PLATE MUST BE AFFIXED AS CLOSE AS
POSSIBLE TO THE EXISTING RATING PLATE
.
THE FOLLOWING MUST BE COMPLETED BY THE INDIVIDUAL
CONVERTING THIS APPLIANCE FROM NATURAL GAS TO
PROPANE GAS.
This appliance has been converted on (date)
MO-DAY-YEAR
to propane gas with Kit * CKP by (name and address of
organization making this conversion)
JOHN SMITH
DISTRIBUTING, 1234 ANYWHERE RD., ANYWHERE,
STATE/PROVINCE,
who accepts the responsibility for the correctness of this
conversion.
22330A
WARNING!
Do not leave the pressure too low or too high.
This will create a safety hazard!
between 10 and 11 water column (optimum
pressure is 10.5 WC) for propane. If the outlet
gas pressure is incorrect, contact the gas
supplier or Heatilator Technical Services. When
finished, turn the valve back to the PILOT
position, turn off the burner, disconnect the
Manometer and tighten the outlet pressure tap
screw.
Step 8 - Resetting the Appliance
a.
Replace the logs as shown on page 27.
b.
Replace the glass and screen as shown on
page 27.
5. WIRING
a. Wall Switch Wiring
The installer shall supply a UL-listed or in
Canada, a CSA-listed wall switch. This appliance
was tested with eighteen feet of UL listed 18 ga.
Type CL2 105°C, two conductor thermostat wire.
If other wiring materials are used they shall
comply with local codes. In the absence of local
codes, they shall comply with the
National
Electrical Code ANSI/NFPA 70-latest edition or
Canadian Electrical Code CSA C22.1.
b. Standing Pilot Ignition
A wiring diagram is shown in Figure 38. You must
wire for the fan kit supplied with this appliance at
installation to avoid reconstruction.
Figure 38 - Standing Pilot Ignition Wiring Diagram
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with
National electric Code ANSI/NFPA 70-
latest edition
or the
Canadian Electric Code CSA C22.1.