2
598-1307-01
ON-TI
ME
RANGE
DU
AL BRITE™
MIN
MA
X
TE
ST
1 5 20
M
INUTES
OFF 3
6 DUSK
TO
H
OUR
DAW
N
LAMP MOD
E
NORMAL
SOFT FLAS
H
W
ire
t
he
l
ight
C
ontrol
These instructions show the sensor wired to floodlamps.
The
white sensor wire
is
neutral.
The
black sensor
wire
is
hot.
The red wire is the switched “hot” wire. The
lighting load
(300 Watts, 2.5 A max. incandescent only)
is placed across the
white
and
red wires.
3.
BLACK
CONTROL
WIRE &
BLACK
JUNCTION BOX WIRE
1. ALL
WHITE
WIRES
2.
RED
CONTROL WIRE
&
BLACK
LAMP WIRES
Optional:
Connect additional
load across the white and red
wires. Total lighting load includ-
ing lampheads on fixture must
not exceed 300W (2.5A).
Junction Box
M
ount
t
he
l
ight
❒
Follow the instructions that came with your light fix-
ture for mounting and adjusting the light fixture.
❒
Keep regular PAR-38 lamps at least 1" (25 mm) from
the sensor. Halogen lamps should be kept at least 2"
(51 mm) from the sensor.
INSTALLATION
For eave mount only:
❒
Swing the sensor head towards the clamp screw
joint.
If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.
❒
Then rotate the sensor head clockwise 180° so the
controls face down.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
For under eave installation, the sensor head must be
rotated
as shown in the next two steps for proper opera-
tion and to avoid the risk of electrical shock.
Controls
Clamp Screw
Controls
Controls
❒
Remove the existing light fixture, if present.
❒
After screwing the sensor into the wall plate, connect
the junction box wires to the light control wires by twist-
ing together and securing with wire connectors.
WARNING: Turn power off at circuit breaker or
fuse.
Lamp Holders