29
Appliance Requirements
This appliance requires that 110-120 VAC be wired
to the factory installed junction box. Maintain correct
polarity when wiring the junction box.
NOTE
ELECTRICAL WIRING MUST BE INSTALLED BY
A LICENSED ELECTRICIAN.
Optional Accessories
Remote control kits require that 110-120 VAC be
wired to the fireplace junction box.
CAUTION
DISCONNECT REMOTE CONTROLS IF ABSENT
FOR EXTENDED TIME PERIODS TO PREVENT
ACCIDENTAL FIREPLACE OPERATION.
Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less of
16 A.W.G. minimum Romex wire and connect it to
the fireplace ON/OFF switch pigtails.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OP-
ERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
Figure 19. Intermittent Pilot Ignition (IPI) Wiring Diagram
If Your Fireplace
Has Intermittent
Pilot Ignition (IPI)
NOTE 1:
Ignition module, valve, pilot and wall switch operate on 3 volts.
120 VAC is required at junction box unless equipped with battery back-up.
NEUTRAL
GROUND
REMOTE
CONTROL
HOT
LOW VOLTAGE
SEE NOTE 1
ON/OFF
WALL SWITCH
VALVE
OPTIONAL
REMOTE
BROWN
BROWN
RED
ORANGE
GREEN
BLACK
OPTIONAL
BATTERY
BACK-UP
BLACK (IGNITOR)
BLACK (SENSOR)
BLACK
GROUND TO
FIREPLACE
CHASSIS
PILOT ASSEMBLY
AND VALVE ASSEMBLY
MUST BE GROUNDED
(COMMON GROUND
WITH FIREPLACE
CHASSIS)
SPARK TO
PILOT IGNITOR
IGNITOR
MODULE
3V
120 VAC
JUNCTION BOX
TRANSFORMER
3V
REM
FAN OUTLET RECEPTACLE
(NO FAN OPTION)
PLUG-IN
3V TRANSFORMER
FLAME SPARKER /
SENSOR
LOW VOLTAGE
SEE NOTE 1
WALL SWITCH
OPTIONAL
BATTERY
BACK-UP
IGNITION
MODULE
(3V)