10
Step 8 Lighting
your fireplace
Standing Pilot Fireplaces
Be sure to read and follow all safety information
shown on the previous page and elsewhere in this
Owners Guide
. And be sure to read and follow all
safety and lighting instructions found in the controls
compartment of your fireplace. A picture of this is
shown in Figure 1.
The drawing below shows the position of the gas
valve control and the pressure regulator knob on
various standing pilot control valve models.
To increase or
decrease the burner
flame height:
Rotate the pressure
regulator knob
clockwise to HI to
increase the flame
height and
counterclockwise to LO
to decrease the flame
height.
To turn the burner
flame on or off:
Use the fireplace
ON/OFF rocker switch,
wall switch, or remote
control kit.
For Optimum
Efficiency:
Turn the control valve to
OFF
when the
appliance is not in
operation.
Figure 6. Gas Valve Control and Pressure
Regulator Knob
CAUTION
DURING THE INITIAL PURGING AND SUBSE-
QUENT LIGHTINGS OF YOUR FIREPLACE, NEV-
ER ALLOW THE GAS VALVE CONTROL KNOB TO
REMAIN DEPRESSED IN THE PILOT POSITION
WITHOUT PUSHING THE RED IGNITOR BUTTON
AT LEAST ONCE EVERY SECOND.
STANDING PILOT CONTROL VALVES
VALVE CONTROL KNOB
VALVE
CONTROL
KNOB
PRESSURE
REGULATOR KNOB
STANDARD VALVE
VARIABLE VALVE
STANDARD VALVE
VARIABLE VALVE
VALVE CONTROL KNOB
PRESSURE
REGULATOR
KNOB