Wiring
Figure 17. Standing Pilot Ignition Wiring Diagram
If Your Fireplace
Has Standing
Pilot Ignition
Appliance Requirements
This appliance
DOES NOT
require 110-120 VAC
to operate.
WARNING: DO NOT CONNECT 110-120
VAC TO THE GAS CONTROL VALVE OR
THE APPLIANCE WILL MALFUNCTION
AND THE VALVE WILL BE DESTROYED
.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
NOTE
ELECTRICAL WIRING MUST BE INSTALLED BY
A LICENSED ELECTRICIAN.
CAUTION
DISCONNECT REMOTE CONTROLS IF ABSENT
FOR EXTENDED TIME PERIODS TO PREVENT
ACCIDENTAL FIREPLACE OPERATION.
Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less length
of 18 A.W.G. minimum wire and connect it to the
fireplace ON/OFF switch pigtails.
DO NOT CONNECT
110-120 VAC TO THE WALL SWITCH OR THE
CONTROL VALVE WILL BE DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OP-
ERATION. VERIFY PROPER OPERATION AFTER
SERVICING
Note:
Some models may not have a Hi-temp.
Limit Switch or may have this switch
wired in series with the on/off switch.
!