NOTE:
A Quadra-Fire outside air kit; 811-0872, is
available through your Quadra-Fire Dealer
to be used as a the outside air option, but is
required for mobile home installations. See
page 26 Section 7 Mobile Home Installation for
more details.
B. Outside Air Kit Instructions
1.
Measure distance from floor to air vent opening in
appliance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inches
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
3.
Use hose clamp to secure flex pipe to collar assembly.
4.
Slide trim ring over flex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second
hose clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
Flex Hose
Hose Clamp
Collar
Assembly
Trim Ring
Hose Clamp
Termination
Cap Assembly
Figure 23.4
Attach hose clamp to
intake air collar
Outside air
flex pipe
Figure 23.5
Drill these 2
holes
Figure 23.1
Verify gasket is installed
between adapters
Figure 23.2
Figure 23.3
12. Using the electric drill with #26 drill bit; drill 2 holes into
the left side of the hopper. Add two screws to secure
shroud assembly to the appliance
(Figure 23.1)
.
13. Attach appropriate the top vent adapter; either 3 inch
or 4 inch depending on size of vent pipe using for your
application. Attach this to the top of Rear Shroud Top
Vent
(Figures 23.2 and 23.3)
.
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage