10
07/22
7027-804H
C
D
A
B
D. Minimum Opening for Masonry &
ZC Fireplaces
C. Masonry Chimney and Fireplace
Clearances
Figure 10.1
Figure 10.2
SIDE
TRIM
HEARTH
EXTENSION
28-1/2 in
(724mm)
SIDE
W
ALL
TOP TRIM
19-3/4 in
(502mm)
19-3/4 in
(502m)
18-1/4 in
(464mm)
Figure 10.3
FIREPLA
CE FR
ONT SURF
ACE
MANTEL
USA & CANADA
17 in (432mm)
37-1/2 in
(952mm)
12 in
max *
16
(406mm)
Location
Inches Millimeters
A
Height (Maximum
Hopper Adjustment)*
22-1/4
565
Height (Minimum
Hopper Adjustment)*
19-3/4
502
B Front Width
29-3/4
756
C Rear Width
22-1/2
572
D Depth
12-5/8
337
*HEIGHT:
The Classic Bay 1200 Insert has the option
of an adjustable hopper from 22 inches
for the maximum to 19-1/2 inches for the
minimum. Add a 1/4 inch to the adjustment
for clearances for any measurement in
between the maximum and the minimum
height. The Maximum and minimum are
already calculated for you in the above table
for convenience.
E. Hearth Extension
Use a Type II non-combustible floor protector, extending
beneath the appliance and to the front, and to the sides as
indicated in sub-section
F. Floor Protection on page 11
.
The floor must be non-combustible or otherwise adequately
protected from radiant heat given off by the appliance and
from sparks and falling embers. A layer of thin brick or
ceramic tile over a combustible floor is not sufficient.
NOTE:
Minimum opening dimensions include a 1/4”
(6mm) clearance around unit.
NOTE:
If trim measurement is over 3/4 in (19mm)
in depth use mantle or side clearances
to combustibles.
WARNING
Fire Risk.
Hearth pads must be installed exactly as
specified. High temperatures or hot embers
may ignite concealed combustibles.
Summary of Contents for Quadra-Fire CB1200