TitanMig Pulse 270/3500/5000 Operators Manual
Issue. A 0516
21
1.8 TMP welding machine startup Settings.
Some welding parameters of TMP series welding machine could be adjusted through the startup Settings
menu, and the operation process as following
:
1) Press on
key, and turn on the power switch of the machine at the same time.
2) After few seconds, it enters the Startup Settings Menu, and LED display "Preg" as Figure 3.3.1.
3) Press
to choose
, then the left part of the LED display the parameter name, and
right part of the LED display the parameter value.
4) Turn the left side
to choose the parameter name, turn the right side
to adjust the
parameter value.
5) Press , the LED will display "Finished", means the parameter has been reset and stored. Then
restart the machine and weld.
Adjustable parameters name of startup Settings as following:
1) Pre-gas flow time (PreG):
Adjustable from 0-15s, the default value is 0.1s. It works for MIG, Pulse
MIG, Double Pulse MIG, TIG, Pulse TIG and Spot TIG.
2) Post-gas folw time (PosG) :
Adjustable from 0-15s, the default value is 0.1s. It works for MIG, Pulse
MIG, Double Pulse MIG, TIG, Pulse TIG and Spot TIG welding processes.
3) Soft start wire feed speed (Stfd) :
Adjustable from 1-22 m/min, and also can be set at automatic. It
works for MIG, Pulse MIG and Double Pulse MIG welding process.
4) Inch wire feed speed (Infd) :
Adjustable from 1-22 m/min.
5) Master station MACID (NetP)
: Master station MACID of Devicenet: 0-63.
6) Slave station MACID (NetS) :
Slave station MACID of Devicenet: 0-63.
7) Device net baud rate (Netb) :
0-125 k, 1-250 k, 2-500 k
8) System Set 1 (Set1) :
Bit0 = 1 means allow the simulation remote control, 0 means banned.
9) System Set 2 (Set2)
: temporary undefined.
10) Wire feed machine coefficient (Fdp),
wire feed machine constant (Fdc) : according the different
wire feed motor, setting up different coefficient. First Type, 24V, 22M/Min, 5A motor: Fdp = 400; Fdc =
426; Second Type, 24 v, 22 m, 3.5 A motor: Fdp = 371; Fdc = 400;
11) Setting up Password (Pas1, Pas2, Pas3, Pas4)
: function password settings.
Summary of Contents for TitanMig Pulse 2700
Page 2: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 ...
Page 36: ...TitanMig Pulse 270 3500 5000 Operators Manual Issue A 0516 32 4T Special 2T ...
Page 53: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 49 ...
Page 65: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 61 6 0 Electrical Diagram ...
Page 70: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 66 ...
Page 71: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 67 ...