TitanMig Pulse 270/3500/5000 Operators Manual
Issue. A 0516
20
MIG/MAG standard synergic welding
MIG/MAG single pulse synergic welding
MIG/MAG double pulse synergic welding
When a process is selected, the LED on the relevant symbol lights up.
20.
Save Button:
For two purposes: store the welding parameters and startup Settings menu
21.
Function
Lights up when under welding process.
lights up when under no-load working
lights up if an error has occurred
Lights up when connecting Robot
Lights up when connecting other equipments
1.7 Welding parameters storage and recall
TMP series can store 100 sets of welding parameters (Job0—Job99). The suitable welding parameters
value for different welding application can be stored at any time. Its very convenience to recall the stored
welding parameter when use it next time. No need to preset and adjust the welding parameter value each
time before welding.
For Job 0
, it’s specially used for automatically memory storage, which can store the last welding parameter
automatically. The last welding parameter can be recalled from Job 0 when restart the welding machine.
Operation process of recall as follow:
1) Press
to choose the display value as job. 23
2) Turn
to alter the Job number as 0.
3) The LED will be display the welding parameter which has been used last time.
For Job 1-99,
it’s used for manual storage, Operation process as follow:
1) LED displays the welding parameters which will be stored.
2) Press
to choose the display value as job.
3) Press
, the front of the Job number will display "
-
"
4) Turn
to choose the Job number as “XX”.
5) Press
, the LED will display "Finished", means the parameter has been stored to the Job number
“XX”.
Operation process of recall as follow:
1) Press
to choose the display value as job.
2) Turn
to choose the Job number as “XX”.
3) The LED will be displayed the welding parameters which has been stored in Job “XX”.
Summary of Contents for TitanMig Pulse 2700
Page 2: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 ...
Page 36: ...TitanMig Pulse 270 3500 5000 Operators Manual Issue A 0516 32 4T Special 2T ...
Page 53: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 49 ...
Page 65: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 61 6 0 Electrical Diagram ...
Page 70: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 66 ...
Page 71: ...TitanMig Pulse 2700 3500 5000 Operators Manual Issue A 0516 67 ...