-------------------------------------------------------------------------------------------ICS OPERATIONS MANUAL
HealthCare Information, LLC
24
PILLOW SPEAKER OPERATION
See page 21 for information on pillow speaker type selection.
See pages 13 and 21 to disable the TV’s internal speakers or turn on pillow speaker sound.
The BM13II has a ¼” jack for pillow speaker connection. A one button analog pillow speaker, digital pillow speaker set for
Zenith or Philips code, HCI Visitor station or a Sip and Puff device can be used.
Pin Out
Sip and Puff control is via mechanical switch closure between Tip or Ring and Common.
Starting with the set off and switch closure between Ring and Common will turn the set on. Once set is on a momentary closure
will change the channel one channel. Maintaining the switch closure for about 3 seconds will change direction of the change.
For instance if channel change was up to the next higher channel the direction will change to down and change to the next lower
channel. The change is indicated on the screen. Holding the closure for about 5 seconds will turn the set off. A single button
pillow speaker will also function this way.
A switch closure between Tip and common will cause the volume to change. Maintaining the switch closure for about 3 seconds
will change direction of the change. For instance if volume change was up the direction will change to down. The change is
indicated on the screen. Holding the closure for about 5 seconds will mute the sound. The next closure will un-mute the sound.
A sip and puff device must be a two function device to control volume. Single function devices can only control channel change
and power.
NOTE: When the set is set for Sip and Puff operation audio is not available from the pillow speaker jack.
IR BANDS
There are four IR bands available. Bands one and two are for HCI IR remote controls. To change the IR band of the HCI IR
remote control press and hold the power button for 10 seconds. Bands 3 and 4 are for universal IR remotes. Band 3 is for
Magnavox codes and band 4 is for Apex codes. You can change IR bands in the setup menu (see page 20) or by pressing the
VOL+ and CH+ buttons on the front panel at the same time.
SIP and Puff Connections
Tip
Volume/Mute
Ring
Channel/Power
Sleeve Common
Summary of Contents for RM26ICS RoomMate
Page 1: ...ICS RoomMate Operations Manual MODEL RM26ICS and RM32ICS REVISION 1 0 TM ...
Page 2: ......
Page 26: ... ICS OPERATIONS MANUAL HealthCare Information LLC 26 MENU TREE ...
Page 27: ... ICS OPERATIONS MANUAL HealthCare Information LLC 27 ...
Page 33: ... ICS OPERATIONS MANUAL HealthCare Information LLC 33 SPECIFICATIONS DIMENSIONS 26 INCH ...
Page 34: ... ICS OPERATIONS MANUAL HealthCare Information LLC 34 SPECIFICATIONS DIMENSIONS 32 INCH ...
Page 35: ... ICS OPERATIONS MANUAL HealthCare Information LLC 35 GENERAL SPECIFICATIONS ...
Page 37: ......
Page 38: ...HCI ALSO OFFERS 22 26 32 42 SIZES Copyright 2011 HealthCare Information LLC TM ...
Page 39: ......
Page 40: ......