Modules and transducers
Quantum
X
I3031-14.0
HBM: public
127
Notice
The MX471B is not a traditional data logger that logs the
complete CAN data stream on the bit level. The paramet
erized node “listens” on the CAN bus and extracts the
signals from the relevant CAN messages to transmit
them as measured values.
8.10 MX1601B amplifier
You connect up to 16 freely configurable inputs for
voltage (10 V, 100mV) or current (20mA) or current-fed
piezoelectric sensors (IEPE) to the MX1601B.
The transducers are connected via 8-pin plug terminal
connectors (Phoenix Contact FMC 1.5/8-ST-3.5-RF (or
der no. 1952089)).
All measuring channels are electrically isolated from one
another and from the power supply. When using the ad
justable transducer excitation, electrical isolation from the
supply voltage of the amplifier is not required.