Manual System Operation

While the main objective of the Aqua Plus 16v is to automate the operation of your pool/spa system, there may be

certain times when you want to override the automatic operation and control the equipment manually.  To operate

the pool equipment manually while keeping the automation active, push the corresponding button on the remote

keypad or one of the remote controls.  Note that if you turn an output on manually, it will remain on until either you

turn it off manually, or the next time the programmed automatic operation would normally turn that output off.

Example:  the filter pump is programmed to run from 9:00A to 5:00P daily.  If you turn the filter pump on manually

at 8:00PM, it will run continuously until the next day at 5:00PM at which time it will turn off and follow the normal

program from then on.  Manually turning off an output works in a similar fashion.

Output Names

The Aqua Plus 16v is shipped from the factory with each output labeled with a generic name (e.g. AUX1, VALVE3,

etc.). One of the features in the software (see Configuration Menu, page 17) is that each output can be assigned a

new name that is more descriptive of the equipment being controlled. This makes it much easier to operate all of the

equipment on your pool without having to memorize what each output controls. Insert name labels are also pro-

vided to be placed next to each display pushbutton. Since there is no way to know how your particular system is

configured, this manual will use the original generic names for each output.

Pool Filter Pump

The pool filter pump can be manually operated whether in Standard (single pump) or Dual Equipment (separate

pumps for both pool and spa) mode.  When in Standard mode, the display will refer to the pool filter pump as

“FILTER”.  When in Dual Equipment mode, the display will read “POOL FILTER”.

Single Speed Filter Pump:

  If the pump is currently off, press the “FILTER” button to turn on the pump.  Pressing

the “FILTER” button again will turn off the pump.  However, if there is a heater in the system, and it is operating,

and the “Heater Cooldown” feature is enabled (Configuration Menu) then:  when you press the “FILTER” button

to turn off the filter, only the heater will turn off, the “FILTER” LED will flash and the display will indicate “Heater

Cooldown”.  At this point the filter pump will automatically turn off after 5 minutes of heater cooldown operation.

If you want to override the heater cooldown, simply press the “FILTER” button again to turn off the filter pump.

44

Aux1 - Aux14

(On/Off)

Check System LED

Menu and Navigation Buttons

Display

Valve4 or Heater2

(See Configuration Menu)

System Off (remote displays)

or 

Service (main unit display)

Air Sensor

94ºF

Cell Temp Sensor

77ºF

Solar Sensor

Short circuit

Water Sensor

Open circuit

Spa Sensor

Open circuit

No function

No function

No function

No function

No function

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

NOTE: If Pool and Spa-Dual is selected, the water sensor will display as “Pool Sensor”.

If the sensor appears to operating properly, then the temperature will be displayed.  If this temperature

is not correct then check the placement of the sensor.  If the problem is not placement related, then the

sensor will, most likely, require replacement.  If the display is “Open Circuit” or “Short Circuit” then

check the wiring to the sensor and also make sure that the wires are secure in the terminal block in the

Aqua Plus 16v main unit.

Main Software

Revision 4.00

Display Software

remote-08 r3.10

Exp. Unit Software

Revision 1.10

RF Base Software

r1.20  ID:1234

Pool Filter Bridge

Software r1.00

6B Spa Software

Remote A r1.00

Pool Filter VSC

Software r1.00

Digital Spa Software

Remote B r1.00

CL Module Software

Revision 1.00

CL Light Software

+ to view

CL LT1 Software

App:1.00 BL:1.02

Spa Filter Bridge

Software r1.00

Spa Filter VSC

Software r1.00

No function

No function

No function

No function

No function

No function

No function

No function

No function

Press to view the software revisions of detected lights

Press to view the software revisions of detected lights

No function

No function

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next ColorLogic 4.0 light/menu item

Move to previous/next menu item

Move to previous/next menu item

Chemistry Sense

Software r1.00

No function
Move to previous/next menu item

Available displays depend on configuration.

  If you call the Hayward Technical Service Dept. for

assistance, they may ask for the software revisions of both the main unit and each of the display/

keypads or other devices that are attached to the system.  Note that it is possible that different

display/keypads have different software revision levels.  For this reason, it is advisable to check this

diagnostic menu item on every display.

Summary of Contents for Aqua Plus 16v

Page 1: ...required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manu...

Page 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Page 3: ...enu 32 Quick How To Operate the Spa Manually 33 Guide Operate the Spa Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start Stop Superchlorination 34 Program a Timeclock 3...

Page 4: ...solarheater Bothmanualandautomatic programmed operationare available All of the control functions can be programmed at a display keypad which is part of the main unit typically located near the pool e...

Page 5: ...installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation special...

Page 6: ...Valve4 or Heater2 See Configuration Menu System Off remote displays or Service main unit display Air Sensor 94 F Cell Temp Sensor 77 F Solar Sensor Short circuit Water Sensor Open circuit Spa Sensor O...

Page 7: ...tandard Relay Manual operation of all relays LIGHTS AUX1 AUX6 is identical Assuming that the relay iscurrentlyoff simplypresstheappropriatebuttontoturnontherelay Iftherelaydoesnotturnon itprobablyis d...

Page 8: ...the time remaining will be displayed on the remote display keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlus16vtonormal automatic operation SeeTrouble shooting DiagnosticInformationformor...

Page 9: ...is invalid Cell Power Error If a chlorinator cell power error is detected on the printed circuit board No Flow Filter Pump If the filter pump is on and the flow switch indicates no flow for 15 minutes...

Page 10: ...sary before adding salt High Salt Amps Minerals TheAqua Plus 16v will stop generating chlorine under certain high salt condi tionsinordertoprotecttheinternalelectronicsfromdamage Theonlywaytolowerthes...

Page 11: ...er FILTER 39 System Maintenance Tomaintainmaximumperformance itisrecommendedthatyouopenandvisuallyinspectthecellevery3months oraftercleaningyourfilter TheAquaPlus16vwillremindyoutodothisbydisplayingth...

Page 12: ...peed Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest Move to next menu item Aux2 Speed 9...

Page 13: ...s enabled This setting determines the speed of the pump during low speed pool or spillover operation This value can be set from Lowest Speed to 50 in 5 increments 50 is default For PS models using dua...

Page 14: ...to the distance between the Base Receiver and the remote device being too great or may be due to interference caused by other RF equipment operating in the neighborhood Try using the Change Channel c...

Page 15: ...and filter operation set to pool only the valves will switch to the pool only position Refer to page 12 for general notes regarding timeclock programming For two speed or variable speed pumps this set...

Page 16: ...d stop times to previous next menu item or or Lights CountDn 0 20 Adjust time setting Manual On Off 0 05 0 10 0 015 Move to previous next menu item Note Separate chlorinator output levels for the pool...

Page 17: ...the Lights relay it should be marked on the label inside the door Then press the appro priate button to turn on the jets blower Operate the Spa Automatically 1 Pressthe MENU buttonrepeatedlyuntil Time...

Page 18: ...7P Adjust time setting Adjust time setting Manual On Off 0 05 0 10 0 15 Move between start and stop times to previous next menu item Move to previous next menu item Valve3 all 8 30A to 4 00P Valve3 0...

Page 19: ...of the standardAqua Plus 16v functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Valve3 Button 6 Valve4 Button 7 Aux1 and Button 8 Aux2 Di...

Page 20: ...L 15 T CELL 15 GLX CELL 15 W 30 Group the valve operates when the Group function is initiated and shuts off when the Group function is terminated See valve3 Group section for operation information for...

Page 21: ...ool Only and Spillover are available 29 NOTE The configuration for Valve3 and Valve4 are identical However if Heater2 was enabled then the Valve4 configuration will not appear a single relay is used t...

Page 22: ...en they want to control the filter equipment Asheet of small name labels is included with theAqua Plus 16v main unit and each remote display keypad so that appropriate pushbuttons can be labeled the s...

Page 23: ...name as a help to technicians who may service this system at a later date Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed The...

Page 24: ...d the lights output will be forced off when the external input is active This will have precedence over freeze protection Lights External Input Interlock is not available for solar low speed filter pu...

Page 25: ...can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off the lights relay will alternate between turning on and off when the LI...

Page 26: ...lter is configured for 2 speed operation During default operation high speed mode is used whenever the solar heater is on If Allow Low Speed is enabled low speed pump operation will be allowed during...

Reviews: