Chemistry Config.

 to enter

Press to access Chemistry Config. Wizard
Move to previous/next menu item

Chemistry Configuration Wizard

Requires use of the optional AQL-CHEM Sensing Kit. 

 Following the steps of the Chemistry Config.

Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is

used, can configure the Aqua Plus 16v to generate the correct amount of chlorine to properly sanitize

the pool. Refer to the AQL-CHEM manual for more detailed information.

Pool/Spa Config.

+ to view/change

Pool/Spa Setup

Pool and Spa-Std

Spa Spillover

Enabled

 

Heaters

Htr1=Spa,Htr2=Pool

Filter Operation

Spa Spillover

Push to access Pool/Spa options

Rotates between Pool and Spa-Std 

, Pool and Spa-Dual,

Pool Only, and Spa Only options

(default)

Toggle between Enabled and Disabled 

 Spa Spillover

(default)

Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters

Toggle between Pool Only 

 and Spa Spillover  options

(default)

Move to previous/next configuration menu 

Move to next menu item

Move to next menu item or previous/next configuration menu

Move to next menu item

Move to previous/next configuration menu

if “Pool and Spa-Std or Dual” is 

selected and if “Spa Spillover” is enabled

Spa - CountDn 

00:30

Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item

if “Pool and Spa-Std” is selected

if “Pool and Spa-Dual” is selected

if “Pool and Spa-Std or Dual” is selected

V1=Aux1, V2=Aux2

Disabled

Toggle between Enabled and Disabled (default)

if “Pool Only” or “Spa Only” is selected

Move to previous/next configuration menu

Filter Off Valve

Change: Enabled

Toggle between Enabled 

 and Disabled 

(default)

if “Pool and Spa-Std” is selected

Move to previous/next configuration menu

Pool/Spa Setup

If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect.  If “Pool and Spa-Std” is selected, then
the pool/spa suction and return valve actuators should be connected to the Aqua Plus 16v.  Pressing
the POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and
spa operation.   If “Pool and Spa-Dual” is selected, then only the Pool/Spa return valve actuator
should be connected to the Aqua Plus 16v.

Heaters

This menu will only appear if Pool/Spa setup is set to “Pool and Spa-Dual”.  This allows the heater(s)
to either be shared  between the pool and spa (“Shared” selected) or for Heater1 to be dedicated to the
spa and Heater2 to be dedicated to the pool (“Htr1=Spa, Htr2=Pool” selected).

Spa CountDn

This menu will appear only if Pool/Spa Setup is set to “Pool and Spa-Std”.  This setting is the time,
after you manually switch the Pool/Spa valves to “Spa Only”, until the Aqua Plus 16v automatically
returns the valves to their previous positions. It is programmed in increments of 5 minutes, from
“Manual On/Off” (0 minutes) to 

“21:00” (21 hours).

  The filter is forced on during this time period.

Spa Spillover

When spa spillover is “Enabled” and “Pool and Spa-Std”, the homeowner will be able to rotate
through “Pool Only” (both suction and return valves switched to pool), “Spa Only” (both suction and
return valves switched to spa) and “Spillover” (suction valve switched to pool and return valve
switched to spa) by successive presses of the “Pool/Spa” button.  For “Pool and Spa-Dual”, only
“Pool Only” and “Spillover” are available.

29

NOTE: The configuration for Valve3 and Valve4 are identical.  However, if Heater2 was enabled, then the Valve4 configuration
will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function--it can not do both). For
PS-16, see aux logic on page 27 for control of Valves7, 8, 9 and 10.

Valve3

Disabled

 Freeze

Toggle between Enabled and Disabled (default) Valve3 Freeze 
Move to previous/next configuration menu 

for all functions except group and super chlorinate

Valve3 Config.

+ to view/change

Valve3 Function

Solar

Valve3 Name

Waterfall

Push to access Valve3 options

Rotates between 

Manual On/Off (default), Countdown Timer, 

Timeclock, Solar, In-floor Cleaner, Group, and Super Chlorinate

Move to previous/next configuration menu

Move to next menu item

Valve3

Disabled

 Interlock

Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item

for all functions except solar, group or super chlorinate

for all functions except solar, group or super chlorinate

Rotates between all available names 
Move to next menu item

Valve3 Group

Filter: Unaffected

Valve3 Group

Timer: None(Manual)

Options available depend on the function that is selected

Rotates between Manual On/Off (default),Countdown Timer and Timeclock

Move to previous/next menu item or next configuration menu

Move to next menu item 

for group function only

for group function only

Valve3 Ext Input

Disabled

Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu

if filter pump is set to variable speed

and the relay type is set to standard

Valve3 Pump Spd

Settings Menu

Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu 

Valve3 Name

The Aqua Plus 16v allows you to assign any one of a number of names (e.g. “Cleaner Valve, Waterfall

valve, Solar Valve, etc.) to each of the valve output control function.  This will make the Aqua Plus 16v

much more user friendly to the homeowner when they want to turn various valves on or off or program

the timeclocks.  A sheet of small name labels is included with the Aqua Plus 16v main unit and each

remote display/keypad so that the “Valve3” (and “Valve4”) pushbutton can be labeled the same as the

name that you have assigned.

Valve3 Function

Manual On/Off (default)

 – the valve3 relay will alternate between turning on and off when the

VALVE3 button is pressed.  There is no automatic control logic.  The VALVE3 button can also be used
to turn the valve output on or off.

Countdown Timer

 – the valve3 relay will turn on when the VALVE3 button is pressed and then will

turn off automatically after a programmed time (see Timers Menu in the Operations Manual).  The
VALVE3 button can also be used to turn the output off.

Timeclock

 – the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see

Operations Manual).  The valve3 button can also be used to turn the valve output on or off.

Solar 

 – the valve operates when the filter pump is running and solar heat is available and the water is

less than the desired temperature setting.  Solar heating must be enabled in the “Solar Config. menu
for proper operation to occur.

In-Floor Cleaner

 – the valve switches the water returning to the pool between the in-floor cleaner and

the normal return jets which facilitate efficient surface skimming.  The valve will operate the in-floor
cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the
hour.

Summary of Contents for Aqua Plus 16v

Page 1: ...required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manu...

Page 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Page 3: ...enu 32 Quick How To Operate the Spa Manually 33 Guide Operate the Spa Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start Stop Superchlorination 34 Program a Timeclock 3...

Page 4: ...solarheater Bothmanualandautomatic programmed operationare available All of the control functions can be programmed at a display keypad which is part of the main unit typically located near the pool e...

Page 5: ...installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation special...

Page 6: ...Valve4 or Heater2 See Configuration Menu System Off remote displays or Service main unit display Air Sensor 94 F Cell Temp Sensor 77 F Solar Sensor Short circuit Water Sensor Open circuit Spa Sensor O...

Page 7: ...tandard Relay Manual operation of all relays LIGHTS AUX1 AUX6 is identical Assuming that the relay iscurrentlyoff simplypresstheappropriatebuttontoturnontherelay Iftherelaydoesnotturnon itprobablyis d...

Page 8: ...the time remaining will be displayed on the remote display keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlus16vtonormal automatic operation SeeTrouble shooting DiagnosticInformationformor...

Page 9: ...is invalid Cell Power Error If a chlorinator cell power error is detected on the printed circuit board No Flow Filter Pump If the filter pump is on and the flow switch indicates no flow for 15 minutes...

Page 10: ...sary before adding salt High Salt Amps Minerals TheAqua Plus 16v will stop generating chlorine under certain high salt condi tionsinordertoprotecttheinternalelectronicsfromdamage Theonlywaytolowerthes...

Page 11: ...er FILTER 39 System Maintenance Tomaintainmaximumperformance itisrecommendedthatyouopenandvisuallyinspectthecellevery3months oraftercleaningyourfilter TheAquaPlus16vwillremindyoutodothisbydisplayingth...

Page 12: ...peed Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest Move to next menu item Aux2 Speed 9...

Page 13: ...s enabled This setting determines the speed of the pump during low speed pool or spillover operation This value can be set from Lowest Speed to 50 in 5 increments 50 is default For PS models using dua...

Page 14: ...to the distance between the Base Receiver and the remote device being too great or may be due to interference caused by other RF equipment operating in the neighborhood Try using the Change Channel c...

Page 15: ...and filter operation set to pool only the valves will switch to the pool only position Refer to page 12 for general notes regarding timeclock programming For two speed or variable speed pumps this set...

Page 16: ...d stop times to previous next menu item or or Lights CountDn 0 20 Adjust time setting Manual On Off 0 05 0 10 0 015 Move to previous next menu item Note Separate chlorinator output levels for the pool...

Page 17: ...the Lights relay it should be marked on the label inside the door Then press the appro priate button to turn on the jets blower Operate the Spa Automatically 1 Pressthe MENU buttonrepeatedlyuntil Time...

Page 18: ...7P Adjust time setting Adjust time setting Manual On Off 0 05 0 10 0 15 Move between start and stop times to previous next menu item Move to previous next menu item Valve3 all 8 30A to 4 00P Valve3 0...

Page 19: ...of the standardAqua Plus 16v functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Valve3 Button 6 Valve4 Button 7 Aux1 and Button 8 Aux2 Di...

Page 20: ...L 15 T CELL 15 GLX CELL 15 W 30 Group the valve operates when the Group function is initiated and shuts off when the Group function is terminated See valve3 Group section for operation information for...

Page 21: ...ool Only and Spillover are available 29 NOTE The configuration for Valve3 and Valve4 are identical However if Heater2 was enabled then the Valve4 configuration will not appear a single relay is used t...

Page 22: ...en they want to control the filter equipment Asheet of small name labels is included with theAqua Plus 16v main unit and each remote display keypad so that appropriate pushbuttons can be labeled the s...

Page 23: ...name as a help to technicians who may service this system at a later date Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed The...

Page 24: ...d the lights output will be forced off when the external input is active This will have precedence over freeze protection Lights External Input Interlock is not available for solar low speed filter pu...

Page 25: ...can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off the lights relay will alternate between turning on and off when the LI...

Page 26: ...lter is configured for 2 speed operation During default operation high speed mode is used whenever the solar heater is on If Allow Low Speed is enabled low speed pump operation will be allowed during...

Reviews: