Hayward Aqua Plus 16v Operation Manual Download Page 15

12

Wireless

Channel:  1

Reteach all

wireless units

Confirm Change:

+ to proceed

Push to confirm the channel change

Change the desired wireless channel (1 - 5)

Move to previous (Teach Wireless) menu

If channel is changed, move to confirmation menu

Move to previous/next menu item

If channel is not changed, move to previous/next menu item

This setting changes the channel to be used by the wireless base station and remote(s).  If the channel

is changed and confirmed, all wireless remote will have to be re-taught. This menu will only appear if

a wireless base station is connected to the Aqua Plus 16v.

Timers Menu

The Timers Menu allows you to set all timeclock and countdown timers which control the automatic operation of

your pool/spa system.

Each timeclock has a single on/off program per day.  All of the timeclocks are setup (Configuration Menu) either as

“all days” or “weekends/weekdays”.  If “weekends/weekdays” are selected, you will need to program on times for

both weekdays and weekends and off times for both weekdays and weekends, even if you want them to be the

same.  All times are adjusted in 15 minute increments (9:00A, 9:15A, 9:30A, etc.).  If you program the on time

equal to the off time (“10:00A to 10:00A”) the output will NEVER turn on.  If you want to disable a timeclock, you

can set the on time equal to the off time and you will notice the times disappear and the display simply shows “Off”.

If, at a later time, you wish to re-activate the timeclock, simply press either the “+” or “-“ buttons to go back to a

normal timeclock programming display.

The Countdown timer is programmed in increments of 5 minutes from “Manual On/Off” (0 minutes) to a maximum

of “21:00” (21 hours).  When “Manual On/Off” is displayed, the countdown timer is disabled and the output will be

manually controlled.  When a countdown timer is equal or greater than “0:05”, pressing the appropriate output

button will turn the output on and start the timer.  Pressing the button again will turn the output off or, when the

programmed time has elapsed, the output will automatically turn off.

!

  

Important:

  

All of the displays shown below use the default generic names for each function or

output. The Aqua Plus 16v allows more descriptive names to be assigned to each piece of equipment

(refer to the section regarding the Configuration Menu for more information).

For one speed pumps, this is the first filter timeclock and will determine the normal hours of filtration

for the pool.  For pool/spa combination systems with spillover enabled and filter operation set to

“spillover”, the valves will automatically switch to spillover mode at the start of the filtration period.

For pool/spa combination systems with spillover enabled and filter operation set to “pool only”, the

valves will switch to the pool-only  position.  Refer to page 12 for general notes regarding timeclock

programming.

For two speed or variable speed pumps, this setting will be the period of time when the pump runs at

high speed (the word “Filter T1” in the display will be replaced with “Filter Hi”).  There is a separate

timeclock for the low speed operation (see below).  If the high speed and low speed periods overlap,

then the pump will operate in low speed during the overlap period.

There are several reasons the filter pump may be running at times other than the timeclock period set

above.  These include super-chlorination, spa operation, manual operation, heater cooldown, freeze

protection, heater-extend and solar-extend.

Chlorinator Operation / Water Chemistry

General Water Chemistry

Salt is required only if you are using the chlorinator features on the Aqua Plus 16v Control. If you are NOT using

the chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to

the description of the Aqua Plus 16v configuration menu for information on enabling/disabling the chlorinator (see

page 17).

Water Chemistry

The table below summarizes the levels that are recommended by the Association of Pool and Spa Professionals

(APSP).  The only special requirements for the Aqua Plus 16v are the salt level and stabilizer.

Saturation index

The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water

“balance”.  Your water is properly balanced if the Si is 0 ±0.2.  If the Si is below -0.2, the water is corrosive and

plaster pool walls will be dissolved into the water.  If the Si is above +0.2, scaling and staining will occur.  Use the
chart below to determine the saturation index.

35

Set Day and Time

Wednesday 10:37P

Adjust time setting

Move between start and stop times & to previous/next menu item

Filter  T1-all 

8:30A to 4:00P

Filter  T1-wkend

8:30A to 4:00P

Filter  T1-wkday
8:30A to 4:00P

Adjust time setting

Adjust time setting

Move between start and stop times & to previous/next menu item

Move between start and stop times & to previous/next menu item

or

ºC       ºF       

 

Ti

Calcuim

Hardness

Ci

Total

Alkalinity

Ai

53

60

66

76

84

94

103

12

16

19

24

29

34

39

.3

.4

.5

.6

.7

.8

.9

How to use: 

Measure pool pH, temperature, calcium hardness,

and total alkalinity.  Use the chart above to determine Ti, Ci,and

Ai from your measurements.  Insert values of pH, Ti, Ci and Ai
into the above equation.  If Si equals .2 or more, scaling and 

staining may occur.  If Si equals -.2 or less corrosion or irritation

may occur. 

Si = pH + Ti + Ci + Ai - 12.1

-.2

0

.2

CORROSIVE

SCALING

75

75

100

100

125

125

150

150

200

200

250

250

300

300

400

400

600

600

800

800

1.5

1.9

1.6

2.0

1.7

2.1

1.8

2.2

1.9

2.3

2.0

2.4

2.1

2.5

2.2

2.6

2.4

2.8

2.5

2.9

OK

Summary of Contents for Aqua Plus 16v

Page 1: ...required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manu...

Page 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Page 3: ...enu 32 Quick How To Operate the Spa Manually 33 Guide Operate the Spa Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start Stop Superchlorination 34 Program a Timeclock 3...

Page 4: ...solarheater Bothmanualandautomatic programmed operationare available All of the control functions can be programmed at a display keypad which is part of the main unit typically located near the pool e...

Page 5: ...installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation special...

Page 6: ...Valve4 or Heater2 See Configuration Menu System Off remote displays or Service main unit display Air Sensor 94 F Cell Temp Sensor 77 F Solar Sensor Short circuit Water Sensor Open circuit Spa Sensor O...

Page 7: ...tandard Relay Manual operation of all relays LIGHTS AUX1 AUX6 is identical Assuming that the relay iscurrentlyoff simplypresstheappropriatebuttontoturnontherelay Iftherelaydoesnotturnon itprobablyis d...

Page 8: ...the time remaining will be displayed on the remote display keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlus16vtonormal automatic operation SeeTrouble shooting DiagnosticInformationformor...

Page 9: ...is invalid Cell Power Error If a chlorinator cell power error is detected on the printed circuit board No Flow Filter Pump If the filter pump is on and the flow switch indicates no flow for 15 minutes...

Page 10: ...sary before adding salt High Salt Amps Minerals TheAqua Plus 16v will stop generating chlorine under certain high salt condi tionsinordertoprotecttheinternalelectronicsfromdamage Theonlywaytolowerthes...

Page 11: ...er FILTER 39 System Maintenance Tomaintainmaximumperformance itisrecommendedthatyouopenandvisuallyinspectthecellevery3months oraftercleaningyourfilter TheAquaPlus16vwillremindyoutodothisbydisplayingth...

Page 12: ...peed Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest Move to next menu item Aux2 Speed 9...

Page 13: ...s enabled This setting determines the speed of the pump during low speed pool or spillover operation This value can be set from Lowest Speed to 50 in 5 increments 50 is default For PS models using dua...

Page 14: ...to the distance between the Base Receiver and the remote device being too great or may be due to interference caused by other RF equipment operating in the neighborhood Try using the Change Channel c...

Page 15: ...and filter operation set to pool only the valves will switch to the pool only position Refer to page 12 for general notes regarding timeclock programming For two speed or variable speed pumps this set...

Page 16: ...d stop times to previous next menu item or or Lights CountDn 0 20 Adjust time setting Manual On Off 0 05 0 10 0 015 Move to previous next menu item Note Separate chlorinator output levels for the pool...

Page 17: ...the Lights relay it should be marked on the label inside the door Then press the appro priate button to turn on the jets blower Operate the Spa Automatically 1 Pressthe MENU buttonrepeatedlyuntil Time...

Page 18: ...7P Adjust time setting Adjust time setting Manual On Off 0 05 0 10 0 15 Move between start and stop times to previous next menu item Move to previous next menu item Valve3 all 8 30A to 4 00P Valve3 0...

Page 19: ...of the standardAqua Plus 16v functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Valve3 Button 6 Valve4 Button 7 Aux1 and Button 8 Aux2 Di...

Page 20: ...L 15 T CELL 15 GLX CELL 15 W 30 Group the valve operates when the Group function is initiated and shuts off when the Group function is terminated See valve3 Group section for operation information for...

Page 21: ...ool Only and Spillover are available 29 NOTE The configuration for Valve3 and Valve4 are identical However if Heater2 was enabled then the Valve4 configuration will not appear a single relay is used t...

Page 22: ...en they want to control the filter equipment Asheet of small name labels is included with theAqua Plus 16v main unit and each remote display keypad so that appropriate pushbuttons can be labeled the s...

Page 23: ...name as a help to technicians who may service this system at a later date Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed The...

Page 24: ...d the lights output will be forced off when the external input is active This will have precedence over freeze protection Lights External Input Interlock is not available for solar low speed filter pu...

Page 25: ...can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off the lights relay will alternate between turning on and off when the LI...

Page 26: ...lter is configured for 2 speed operation During default operation high speed mode is used whenever the solar heater is on If Allow Low Speed is enabled low speed pump operation will be allowed during...

Reviews: