Install the Hawkeye® 2 RCM - Sprayer: RCM - Sprayer Installation
31
INSTALL THE HAWKEYE® 2 RCM - SPRAYER
ROGATOR ISOBUS TEE CABLE INSTALLATION (P/N 115-0172-325)
1. Locate the ISOBUS Bar inside the ECU cabinet. The ISOBUS bar is adjacent to the edge of the box closest to the
rear of the machine.
FIGURE 8. ISOBUS Bar
2. Disconnect the connector farthest on the right on the ISOBUS bar.
3. Locate the provided RoGator ISOBUS Tee Cable (P/N 115-0172-325).
4. Locate and connect the mating receptacle of the RoGator ISOBUS Tee Cable to the open connector on the
ISOBUS bar.
5. Locate the mating connection on the previously installed ECU cabinet cable (P/N 115-2005-317) and plug it into
the ISOBUS Tee Cable (P/N 115-0172-325).
FIGURE 9. Hawkeye Retrofit Cable Connected to ISOBUS Tee Cable
6. Locate the Raven CANbus bar along the edge of the ECU cabinet furthest from the center of the machine.
7. Locate and disconnect the connector labeled “BIS” from the Raven CANbus bar.
First ISOBUS Bar Connection Removed
Open First
Connection
RoGator ISOBUS
Tee Cable
Connected to the
Hawkeye Retrofit
Cable
RoGator ISOBUS
Tee Cable
Connected to the
First Port of the
ISOBUS Bar
Summary of Contents for AGCO RoGator A Series
Page 8: ...CHAPTER 1 4 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 18: ...CHAPTER 2 14 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 20: ...CHAPTER 3 16 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 28: ...CHAPTER 4 24 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 52: ...CHAPTER B 48 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...