6.2 Checks before commissioning
Check for correct connection
1. Mechanical:
■
fastening to machine, frame and base
2. Electrical:
■
Power supply
■
Control
■
Motor protection circuit
3. Hydraulic:
■
piping and hoses
■
Cylinder
■
Motors
6.3 Set motor protection circuit
Set motor protection circuit
1. Set motor protection circuit to approximately 0.85 to 0.9 times the motor current (I
M
).
✓
When operating normally, the motor protection circuit will not trip prematurely.
✓
When the pressure-limiting valve triggers, the period until shutdown does not become long enough
for the hydraulic uid’s temperature to exceed its permissible maximum.
2. Run a test run to check the motor protection circuit’s settings.
Additional safety precautions against malfunctions are the temperature switches, level switches
and pressure switches. These are optionally available for the hydraulic power pack.
6.4 Filling hydraulic uid
DAMAGE
Dirt must not enter the product
Otherwise, the product may suffer damage
►
Always ll hydraulic uid via the system lter or a mobile lter station.
►
Observe the recommended cleanliness class for the hydraulic uid.
►
Keep all pipes, hose lines, ttings and couplings clean.
►
Carry out all work in a clean environment.
►
Clean hands and clothing before working.
DAMAGE
Accumulator systems
►
Fill accumulators using designated equipment in accordance with the pressure specifications of the
hydraulic schematic.
►
Observe the manufacturer’s corresponding operating instructions and hydraulic schematics.