5.3.4 Connecting level switch and temperature switch
Level switch duty cycle
Dropping hydraulic uid level:
If the amount of hydraulic uid removed during each duty cycle causes the oil level to fall below
the level switch’s monitoring level, take suitable electrical measures to mute the signal until the
uid level rises above the monitoring level once again when the hydraulic uid ows back in at the
end of the duty cycle.
Level switch
for type KA...L (horizontal)
Max. DC/AC switching
capacity
30 VA
Max. DC/AC current
0.5 A (cos
9
= 1)
Max. voltage
230 V AC/DC
Electrical connection
on terminal box/HARTING plug
Circuit symbol
Coding
D
Coding
S
(N/C contact)
(N/O contact)
Level switch
for type KA...S (vertical)
DC/AC switching capacity
10 W
Max. DC/AC current
1 A
Max. voltage
150 V 50/60 Hz
200 V DC
Electrical connection
Line connector industry standard contact gap 9.4 mm
M12x1, 5-pin (coding
M
,
M1
,
M2
,
PM
,
PM1
,
PM2
)
Circuit symbol
Coding
KD
Coding
KS
(N/C contact)
(N/O contact)