AC motor
The actual power consumption depends on the load and can be up to 1.8 x nominal power.
AC motor
Type
Nominal voltage and
power frequency
U
N
(V), f (Hz)
Nominal
power
P
N
(kW)
Rated speed
n
N
(rpm)
Nominal
current
I
N
(A)
Starting
current ratio
I
A
/ I
N
Power
factor
cos
9
Recommend-
ed operating
capacitor
C
B
(μF)
Hydraulic work
value
(pV
g
)
max
(bar cm
3
)
1x230 V 50 Hz
(
0.37
2770
2.5
3.7
0.97
24
100
KAW 21
1x110 V 60 Hz
(
0.37
3340
5.5
3.0
0.96
50
70
1x230 V 50 Hz
(
0.75
2810
4.75
4.4
0.94
32
230
1x110 V 60 Hz
(
0.75
3400
12.0
3.5
0.90
120
175
KAW 22
1x220 V 60 Hz
(
0.75
3400
6.0
3.5
0.90
30
200
1x230 V 50 Hz
(
0.25
1380
1.9
3.0
0.91
18
145
KAW 23
1x110 V 60 Hz
(
0.25
1650
4.4
3.2
0.96
50
100
1x230 V 50 Hz
(
0.5
1390
4.1
2.9
0.95
32
350
1x110 V 60 Hz
(
0.5
1680
9.0
3.3
0.98
65
210
KAW 24
1x220 V 60 Hz
(
0.5
1680
3.9
2.9
0.98
25
275
1x230 V 50 Hz
(
1.1
2770
7.2
4.8
0.98
32
275
1x110 V 60 Hz
(
1.1
3340
15.0
4.0
0.99
100
235
1x220 V 60 Hz
(
1.1
3340
7.2
4.0
0.99
25
275
KAW 26
1x115 V 50 Hz
(
1.1
2750
15.0
4.0
0.96
120
260
1x230 V 50 Hz
(
0.7
1370
5.1
3.0
0.94
36
400
KAW 28
1x110 V 60 Hz
(
0.7
1650
10.5
3.0
0.98
100
315
34/61
B 8010 - 04-2021 - 1.0
HAWE Hydraulik SE