5.3.2 Electrical connection markings
KA 24
KA 28
1
22
S
L1
KS
KTF
E/
P/
H 1.81
HZ 0.59/8.8
- A1/280
- ...
- FSR-24V
- 3x400 V 50 Hz
- 3x400 V 50 Hz
/24 V DC
- G 1/2 x 300
Motor voltage
Electrical connection
Basic type and motor power
Motor type code
■
Coding
KA
= 3-phase motor
■
Coding
KAW
= AC motor
Coding
Comment
No designation
Series (terminal box)
P
HARTING plug
PM, PM1, PM2
HARTING plug with an additional connection M12x1 right, left or on both sides for temperature and/or level
switch (horizontal version), in a vertical version and level switch (coding KD, KS) M12 connection to the level
gauge
Coding PM2 not in combination with suppressor coding PE
M, M1, M2
Terminal box with an additional connection M12x1 right, left or on both sides for temperature and/or level
switch (horizontal version), in a vertical version and level switch (coding KD, KS) M12 connection to the level
gauge
Coding M2 not in combination with suppressor coding E or ller reduction coding B
E, PE
Additional suppressor on terminal box or HARTING plug
5.3.3 Connecting the electric drive
Electrical data
■
Data applies to radial piston pumps and gear pumps
■
The drive motor forms a closed, non-separable unit with the pump.
Connection
part of product
•
For version with HARTING plug, housing with female insert HARTING HAN 1 CE or equivalent, cable cross
section 1.5 mm
2
•
For version with integrated terminal box, at plug sleeve 6.3 AMP
not supplied
•
For terminal box version: cable ttings M20x1.5
•
for option M.., PM.. : Line connector M12x1, 4-pin
•
for option KD, KS (vertical version): M12x1, 5-pole
Protection class
IP 65 according to IEC 60529
The breather lter must be safeguarded against moisture penetration.
Protection class
VDE 0100 Protection class 1
30/61
B 8010 - 04-2021 - 1.0
HAWE Hydraulik SE