OPeRAtiON
General
Use the following procedures to operate Serv-Rite
®
Portable
Shelves and Buffet Warmers.
Read all safety messages in the iMPORtANt SAFety
iNFORMAtiON section before operating this equipment.
eLeCtRiC ShOCk hAzARD: Do not fill SRB and SRBW
models with water. they are dry heat units only, not steam
table units.
Do not place anything on top of glass sneeze guard. it is
not designed to be a weight-bearing component.
Do not slide pans across glass surface, use rough-
bottomed pans, or drop anything on glass surface.
Scratching or breakage may occur. Damage to glass
surface or breakage of glass caused by misuse is not
covered under warranty.
Startup
1. Plug the unit into a properly grounded electrical outlet of
the correct voltage, size, and plug configuration. See the
SPECIFICaTIONS section for details.
2. Move the Power ON/OFF (I/O) switch to the ON (I) position.
• The digital temperature controller will energize and the
current temperature of the heated shelf will appear on
the display.
• The phrase “out 1” will appear in the upper left corner of
the display to show that the base is in heat mode.
• For SRBW-1 SRGBW-1, and SRSSBW-1 models; the
overhead heat lamps will turn on if the LIGHTS ON/OFF
(I/O) switch or the optional dimmer switch was left in the
ON (I) position the last time the unit was on.
WARNING
NOTICE
BURN hAzARD: Some exterior surfaces on unit will get
hot. Use caution when touching these areas.
3. Press and release the
key on the digital temperature
controller to verify the setpoint temperature.
• The setpoint temperature will be shown for 15 seconds.
after 15 seconds, the display will revert to the current
temperature of the heated shelf. To change the setpoint
temperature, refer to “Changing the Setpoint
Temperature” in this section.
Digital Temperature Controller
NOTE: The digital temperature controller is pre-set to a setpoint
temperature of 88°C (190°F) at the factory. Once the
setpoint temperature is changed, the new setpoint
temperature will remain in memory until it is changed
again.
NOTE: SRB and SRG series have a digital temperature
controller with a maximum setpoint temperature setting
of 104°C (220°F), but the maximum operating
temperature of the unit is 93°C (200°F). A temperature
setting above 93°C (200°F) will not harm the unit.
SRSS-1 and SRSSBW-1 models have a maximum
setpoint temperature setting of 90°C (195°F).
Down Arrow
Key
Up Arrow
Key
“out 1”
Celsius
Symbol
SET
Key
CAUTION
Model SRBW-1
Model SRG-1/SRSS-1
Heated
Shelf
Removable
Utensil Tray
Control
Panel
Glass
Sneeze
Guard
Overhead
Heat Lamps
Serv-Rite Components
Summary of Contents for SeRv-Rite SRB Series
Page 86: ...Form No SRCEM 0314 86 NOteS ...
Page 87: ...Form No SRCEM 0314 87 NOteS ...