OPeRAtiON
Digital Temperature
Controller
LIGHTS
ON/OFF
(I/O) Switch
Power ON/OFF
(I/O) Switch
SRBW-1 and SRGBW-1 Control Panel
4. For SRBW-1, SRGBW-1, and SRSSBW-1 models; move
the LIGHTS ON/OFF (I/O) switch or the optional dimmer
switch to the ON (I) position to turn on the overhead heat
lamps.
NOTE: For SRGBW-1 and SRSSBW models; heat generated
by the overhead heat lamps is absorbed by the glass or
stone surface of the heated shelf during the preheat
cycle. This causes the temperature shown on the
display to rise past the setpoint temperature. The
display will return gradually to the setpoint temperature
once a pan or food product is placed on the glass
surface.
5. allow the unit 30 minutes to reach operating temperature
before placing preheated food product.
Shutdown
1. Move the Power ON/OFF (I/O) switch to the OFF (O)
position. The digital temperature controller, heated shelf,
and overhead heat lamps (SRBW-1, SRGBW-1, and
SRSSBW-1 models only) will shut off.
NOTE: For SRBW-1, SRGBW-1, and SRSSBW-1 models: If
the LIGHTS ON/OFF (I/O) switch or the optional
dimmer switch is left in the ON (I) position when the
Power ON/OFF (I/O) switch is moved to the OFF (O)
position, the lights will shut off as well. The lamps will
turn on immediately the next time the Power ON/OFF
(I/O) switch is moved to the ON (I) position.
2. Unplug the power cord and allow the unit to cool before
performing any cleaning or maintenance.
Changing the Setpoint temperature
Use the following procedure to change the setpoint temperature
of the heated shelf.
1. Press and release the
key. The current setpoint
temperature will be shown on the display and ”out 1” will
flash in the upper left corner.
2. Press the
key or
key within 15 seconds to
change the setpoint temperature. If no key is pressed
within 15 seconds, the display will revert to the current
temperature of the unit.
3. Press the
key or wait 15 seconds to lock in the new
setpoint temperature.
NOTE: SRB and SRG series have a digital temperature
controller with a maximum setpoint temperature setting
of 104°C (220°F), but the maximum operating
temperature of the unit is 93°C (200°F). A temperature
setting above 93°C (200°F) will not harm the unit.
SRSS-1 and SRSSBW-1 models have a maximum
setpoint temperature setting of 90°C (195°F).
Locking/Unlocking the Digital temperature
Controller
The keys on the digital temperature controller can be locked to
prevent unauthorized changes to the settings.
To lock the keys of the digital temperature controller:
• Press and hold both the
key and
key at the
same time for over two seconds. The message “Loc” will
appear on the display.
To unlock the keys of the digital temperature controller:
• Press and hold both the
key and
key at the
same time until the message “UnL” appears on the display.