User Manual Version 3.1
31
1 18
F
Connection (Start/Stop) for a FBM
18 F Feeder (max. 42V / 500mA)
8 Feeder
Serial interface to the
feeder (start, stop, speed and gap
determination)
2 AUX
Feeder connection (Start/Stop)
(max. 42V / 500mA)
9 F635
/
2700
Connection (Start/Stop) for a
Streamfeeder 2700 or a RENA
Dreamfeeder version before 2007
(max. 100mA)
3
Relay 1 / 2
Relay outputs for controlling
external devices (e.g. batch kicker
or feeder) (max. 42V / 1A)
10 AF
500
Connection (Start/Stop) for AF 500
(max. 42V / 500mA)
4 Emergency
Stop
Interfaces for emergency stop
system (see next section for a
detailed description)
11
Input 1 / 2
Signal inputs that can be used to
send information to the printer
(e.g. is the upstream device
running)
5 Statuslight
Connection for Hasler signal
lamp (optical signal lamp) (see
section Consumables and
Accessories for more details)
12 USB
USB 2.0 interface to the PC for
sending print data
6 Conveyor
Serial interface (start, stop &
speed) to a Hasler Base
(conveyor)
13 Control
Serial interface to the PC for
control command, status feedbacks
and service purposes. Cannot be
used to send print data to the
printer.
7 Centaur
Serial interface to the
Centaur bulk ink system
14
Ethernet (TCP/IP) interface for
sending print data
Pos: 49 /Bedienungsanleitungen/Geräte neutral/4.6b_Ü2_(Ü3)_Emergency stop connection @ 0\mod_1254129198454_912.doc @ 3831 @ 2
Summary of Contents for HJ 3630
Page 26: ...26 User Manual Version 3 1...