Q-Drive Installation, Operation, and Maintenance Manual
47 of 59
8. Assemble the test and transport plate to seat seal housing. Assemble using 6/off M12x1.25x35
SHCS.
9. Remove the End Cap Insert, Seal Housing, and Guide Bush. Use proper Wrench to remove the
Seal Housing.
10. Remove the plunger retainer plate by removing the 8/off M5x16 SHCS fasteners.
11. Re-assemble the plunger retainer and Drive Rod using 8/off M5x16 SHCS Black. Use Loctite 7471
activator and Loctite 243 thread locker on each fastener Open the inlet valve:
DO NOT DROP
ANYTHING (SCREWS OR FOD) IN THE ACTUATOR!
Torque each M5 screw to 9.5Nm or 7ft•lbs