Q-Drive Installation, Operation, and Maintenance Manual
41 of 59
12. Go to the Service page and tap
Reset Count
to restart the count at zero.
Replacing Oil Filter and Oil
The lubricating oil capacity is 30 litres (8 gallons). Replacement lubricating oil: 20 litres (5.2 gallons),
Syn-Gear EP150. Replace the oil filters each time you replace the oil.
Oil Pump Assembly in the Production unit
Tools
:
31 litre (8.2 gallons) container in total.
o
Container for approximately 1 litre (34 oz.)
o
Container for approximately 30 litres (8 gallons)
Strap wrench
12 mm hoses (2)
Hand pump
Removing the Oil Filters
1. Place the small container under the oil filters to catch any drips.
2. Remove the two 1/8 in breather plugs on the top of the motor end caps.
3. Close the drain valve.
4. Remove the plug.
5. Place the large container under the drain valve or attach a hose from the valve to the container.