Q-Drive Installation, Operation, and Maintenance Manual
36 of 59
About Service and Repair
Select
Settings
and then
Service
to display the parameters and values for the system. The screen
shows the time since the last service. Each Pressure Transducer (PT) and Thermocouple (TC) is
identified by its serial number for calibration traciblity. The serial number and firmware version are
located on the Settings screen and on the Service screen. In any service calls, include the model,
serial number, and firmware version.
Service screen
The Service screen reports the current values for the parameters that control maintenance alarms.
Setting
Definition
Threshold
Main Stroke Count
Each push and return is 2 strokes, which
is 1 cycle. This value cannot be reset.
18,000,000
at 30 CPM
Stroke Count Last Seal Change
When you replace a seal, tap
Reset
Coun
t to restart the count at zero.
1,000 hours
Start Blow By Test
Tap
PAUSE
button to pause the pump
but keep the valve open. A meter senses
if any gas is in the valve, indicating a
leak.
700 SCCM
Pump Running Time
Running time
10,000 hours
Lubricating Oil Change
2000 hours or 1 year
Moisture Absorption Fiilter
Change
1000 hours or 6
months
Rod Seal Change
2000 hours
Gas Inlet Valve Cycles
Valves open when the system is
powered on and close when it is
powered off. One cycle is a valve
opening and closing
2,000,000 cycles
Gas Outlet Valve Cycles
Summary of Contents for Q-Drive QGD Series
Page 1: ...88544_A Q Drive Installation Operation and Maintenance Manual Model QGD and QGT ...
Page 57: ...Q Drive Installation Operation and Maintenance Manual 51 of 59 Points of Connections ...
Page 58: ...Q Drive Installation Operation and Maintenance Manual 52 of 59 ...
Page 59: ...Q Drive Installation Operation and Maintenance Manual 53 of 59 ...
Page 60: ...Q Drive Installation Operation and Maintenance Manual 54 of 59 ...
Page 61: ...Q Drive Installation Operation and Maintenance Manual 55 of 59 ...
Page 62: ...Q Drive Installation Operation and Maintenance Manual 56 of 59 ...