Q-Drive Installation, Operation, and Maintenance Manual
18 of 59
Supervisor Parameters screen
3. Tap one of the modes of operation. The Compressor mode is for continuous operation.
4. For all modes, set the Target Gas Outlet Pressure. Tap
Target Output Pressure
to display the
numeric keypad. Enter the value and tap the
Enter
key
.
5. For Compressor mode, set the deadband value to maintain the pressure level. Tap
Output
Deadband %
. In the keyboard, enter the percent decrease from the target output pressure that is
allowed.
When the pressure reaches the target pressure, the pump pauses and the status becomes
PUMP IS PAUSED
. While the pressure remains within the desired deadband, the pump remains
paused. When the gas output pressure drops below the desired deadband, the pump restarts and
the status is
RUNNING
.
6. To set the pump speed, enter your desired
Cycle Rate button.
7. Open the valve on the supply gas gradually to load the gas slowly.
8. When the status is
Off Ready
, tap the
Start
button. If the status is
Off Not Ready
, check the
active alarms. See “About Alarms.”
Summary of Contents for Q-Drive QGD Series
Page 1: ...88544_A Q Drive Installation Operation and Maintenance Manual Model QGD and QGT ...
Page 57: ...Q Drive Installation Operation and Maintenance Manual 51 of 59 Points of Connections ...
Page 58: ...Q Drive Installation Operation and Maintenance Manual 52 of 59 ...
Page 59: ...Q Drive Installation Operation and Maintenance Manual 53 of 59 ...
Page 60: ...Q Drive Installation Operation and Maintenance Manual 54 of 59 ...
Page 61: ...Q Drive Installation Operation and Maintenance Manual 55 of 59 ...
Page 62: ...Q Drive Installation Operation and Maintenance Manual 56 of 59 ...