Air Driven Air Amplifiers, AA-8, AA-15 & AA-30 • OM-15J
25
Operating and Maintenance Instructions
CE Compliance Supplement
SAFETY ISSUES
A. Please refer to the main section of this instruction manual for general handling, assembly and
disassembly instructions.
B. Storage temperatures are 25°F – 130°F (-3.9°C – 53.1°C).
C. Lockout/tagout is the responsibility of the end user.
D. If the machine weighs more than 39 lbs (18 kg), use a hoist or get assistance for lifting.
E. Safety labels on the machines and meanings are as follows:
General Danger
Read Operator’s Manual
F. In an emergency, turn off the air supply.
G. Warning: If the pump(s) were not approved to ATEX, it must NOT be used in a potentially
explosive atmosphere.
H. Pressure relief devices must be installed as close as practical to the system.
I.
Before maintenance, liquid section(s) should be purged if hazard liquid was transferred.
J. The end user must provide pressure indicators at the inlet and final outlet of the pump.
K. Please refer to the drawings in the main instruction manual for spare parts list and recommended
spare parts list.