Ref.
Item
Function
1
Multimeter
Visual Forward Power in Watts
Visual Reflected Power in Watts
Sound Forward Power in Watts
Sound 2 Forward Power in Watts
Sound Reflected Power in Watts
Module Power Supply in Volts
Module Current in Amps
Exciter Visual Power in Watts
Exciter Video Input Level in mV
Exciter Sync Input Level in mV
Exciter Sound 1 Power in mW
Exciter Sound 2 Power in mW
Exciter Sound Deviation in kHz
Exciter Audio Input Level in mV
2
Selection
Indicates Multimeter reading selection
3
Bar Graph
Indicates Multimeter 0000 to 1000
4
↑
Multimeter selector button roll-down
5
↓
Multimeter selector button roll-up
6
Xmtr ON
Turn Transmitter ON
7
ON Indicator
Lights when Transmitter is ON
8
Xmtr OFF
Turn Transmitter OFF
9
LOCAL
Inhibit Transmitter remote control inputs
10
LOCAL Indicator
Lights when in LOCAL only mode
11
REMOTE
Enable Transmitter remote control inputs
12
Remote Indicator
Lights when in REMOTE mode
13
↑
Raise Visual Power of Transmitter
14
↓
Lower Visual Power of Transmitter
15
↑
Raise Aural Power of Transmitter
16
↓
Lower Aural Power of Transmitter
17
POWER
When ON, indicates AC power to Exciter
18
EXTERNAL INTERLOCK
When ON, indicates external interlock OPEN
19
50V SUPPLY FAULT
When ON, indicates power supply fault condition
20
MODULE FAULT
When ON, indicates one or more of the modules has a fault condition
21
AIR FAULT
When ON, indicates loss of air
22
HIGH VSWR
When ON, indicates a high VSWR condition
24
RF MUTED
When ON, indicates RF Output of Exciter is muted
25
CORRECTOR BYPASS
When ON, indicates one or more corrector boards in the BYPASS mode
26
FREQUENCY UNLOCK
When ON, indicates one or more of the phase lock loops are unlocked
27
VIDEO LOSS
When ON, indicates a loss of input video or video preset delay
28
VISUAL F/B ACT
Indicates a VSWR is causing the visual & aural power to foldback
29
AUTAL F/B ACT
Indicates a VSWR is causing the aural power to foldback
30
50 VOLT POWER
Indicates the 50 volt supply is on
31
5 VOLT POWER
Indicates the 5 volt logic supply is on
32
+12 VOLT POWER
Indicates the +12 volt supply is on
33
-12 VOLT POWER
Indicates the -12 volt supply is on
34
PRE-CORRECTED VISION
IF Corrector output
35
VISION IF MODULATOR
IF Modulator Output
36
PRE-CORRECTED VIDEO
Modulator Input Video
Table 3-2. Transmitter Controls and Indicators
Section III - Operation
888-2457-001
3-3
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum HT EL 2000LS
Page 4: ...This page left blank intentionally...
Page 6: ......
Page 8: ...ii...
Page 12: ...This page left blank intentionally...
Page 38: ...This page left blank intentionally...
Page 46: ...This page left blank intentionally...
Page 54: ...This page left blank intentionally...