Width
26" (66 cm)
Height
72" (183 cm)
Depth
35" (89 cm)
Weight
800 lbs (363 kg)
Environmental Requirements:
Operating Temp. Range
0 to +45 degrees C
(+32 to +113 degrees F)
Maximum temperature rating decreases 2 degrees C per 1,000 foot altitude
above mean sea level.
Humidity Range
0 to 95% Relative Humidity
Maximum Altitude
10,000 feet (2,286 meters)
Power Requirements:
Input
208/240 volts 11 volts, single phase, 50/60 Hz
Regulation
10%
Air System Requirements:
Inlet Air Openings
Rear door and front power module, with filters
Exhaust Air Openings
Amplifier cabinet top, 30" x 8" and amplifier cabinet right rear side (two areas),
6" x 18" and 9" x 11".
Exhaust Temperature
10 degrees C temperature rise above inlet
Allowable Back Pressure
0.05" of water at each cabinet exhaust stack
Acoustic Noise
65dB, @ 3 feet in front of center of transmitter (“A” weighting scale)
Inlet/Exhaust Air Flow
1225 cfm
Table 1-1. Specifications
Continued
Platinum™ Series
1-6
888-2457-001
WARNING: Disconnect primary power prior to servicing.